11.1.4Electromagnetic Induction

The Ideal Transformer Equation

5 min read 9 parts Lesson 5 of 6 1 quiz

0%read

Section 1 of 9The turns-ratio equation

For a transformer, the ratio of the voltages equals the ratio of the numbers of turns:

Vp / Vs = Np / Ns

What the symbols mean: V = voltage (V) · N = number of turns · I = current (A) · p = primary coil · s = secondary coil

where Vp is the primary voltage (V), Vs is the secondary voltage (V), Np is the number of turns on the primary and Ns the number of turns on the secondary. The ratio of the turns can be given in either order as long as the primary and secondary are consistently placed; it can also be written Vs = Vp × Ns/Np.

Section 2 of 9The power equation

For an ideal (100% efficient) transformer, the electrical power in the primary equals the power out of the secondary:

Vp Ip = Vs Is

where Ip and Is are the currents in amperes. This means that if the voltage is stepped up, the current is stepped down by the same factor. Since power P = IV, the equation just states power in equals power out.

Combining the two equations, Is/Ip = Np/Ns: the current ratio is the inverse of the turns ratio.

Section 3 of 9Efficiency

For a real transformer, efficiency is:

efficiency = (power out / power in) × 100% = (VsIs / VpIp) × 100%

It is always less than 100%, because of energy lost as heat in the coils and core. Real transformers have efficiencies around 90–99%.

Section 4 of 9Method for calculations

1
List the known quantities with units and subscripts p and s.
2
Decide if the question is about voltage and turns (use Vp/Vs = Np/Ns) or about currents (use VpIp = VsIs).
3
Rearrange before substituting.
4
Give the answer with a unit and check: a step-up transformer must give Vs > Vp and Is < Ip.

Section 5 of 9Examples of use in practice

A phone charger contains a step-down transformer (then a rectifier), taking 230 V to a few volts. A mains lamp on a model railway uses a transformer to produce 12 V. The grid uses step-up transformers with ratios of the order of 1:15 at the power station and step-down transformers near homes.

Section 6 of 9Further worked reasoning

Suppose a model railway transformer has 1150 turns on the primary connected to the 230 V mains and gives 12 V at the secondary.

1
The number of secondary turns is Ns = Np × Vs/Vp = 1150 × 12/230 = 60 turns.
2
If the ideal transformer supplies 2.0 A at 12 V, the power is 24 W, and the primary current is 24/230 = 0.10 A.
3
It shows how a large step-down in voltage gives a large step-up in current.
4
In an examination always show the formula, the substitution and the answer with unit; any consistent rearrangement is acceptable.

Section 7 of 9Worked examples

  1. A transformer has 200 turns on the primary and 50 turns on the secondary. The primary voltage is 230 V. Find the secondary voltage.

  2. An ideal transformer steps 12 V up to 240 V. The secondary current is 0.50 A. Find the primary current.

  3. A transformer takes 2.0 A at 230 V. The output is 11.5 V at 36 A. Find the efficiency.

Section 8 of 9Key terms

TermMeaning
Turns ratioNp : Ns, equal to the voltage ratio Vp : Vs.
Ideal transformerOne with 100% efficiency.
EfficiencyUseful power out divided by power in, as a percentage.
RectifierCircuit that converts a.c. to d.c.

Section 9 of 9Exam technique

1
Mixing up primary and secondary values.
2
Applying VpIp = VsIs to a non-ideal transformer without allowing for losses.
3
Saying that the current also goes up in a step-up transformer.
4
Leaving out units.
Transformer Golden Equations Physics Standard

Transformer Turns Ratio & Efficiency

Ratio: Vp / Vs = Np / Ns = Is / Ip

  • Step-up reduces grid thermal loss (P = I2R).
  • Laminated core prevents eddy currents.