11.1.4Electromagnetic Induction
The Ideal Transformer Equation
5 min read 9 parts Lesson 5 of 6 1 quiz
Section 1 of 9The turns-ratio equation
For a transformer, the ratio of the voltages equals the ratio of the numbers of turns:
Vp / Vs = Np / Ns
where Vp is the primary voltage (V), Vs is the secondary voltage (V), Np is the number of turns on the primary and Ns the number of turns on the secondary. The ratio of the turns can be given in either order as long as the primary and secondary are consistently placed; it can also be written Vs = Vp × Ns/Np.
Section 2 of 9The power equation
For an ideal (100% efficient) transformer, the electrical power in the primary equals the power out of the secondary:
Vp Ip = Vs Is
where Ip and Is are the currents in amperes. This means that if the voltage is stepped up, the current is stepped down by the same factor. Since power P = IV, the equation just states power in equals power out.
Combining the two equations, Is/Ip = Np/Ns: the current ratio is the inverse of the turns ratio.
Section 3 of 9Efficiency
For a real transformer, efficiency is:
efficiency = (power out / power in) × 100% = (VsIs / VpIp) × 100%
It is always less than 100%, because of energy lost as heat in the coils and core. Real transformers have efficiencies around 90–99%.
Section 4 of 9Method for calculations
Section 5 of 9Examples of use in practice
A phone charger contains a step-down transformer (then a rectifier), taking 230 V to a few volts. A mains lamp on a model railway uses a transformer to produce 12 V. The grid uses step-up transformers with ratios of the order of 1:15 at the power station and step-down transformers near homes.
Section 6 of 9Further worked reasoning
Suppose a model railway transformer has 1150 turns on the primary connected to the 230 V mains and gives 12 V at the secondary.
Section 7 of 9Worked examples
A transformer has 200 turns on the primary and 50 turns on the secondary. The primary voltage is 230 V. Find the secondary voltage.
Vs = Vp × Ns/Np = 230 × 50/200 = 57.5 V. It is a step-down transformer.
An ideal transformer steps 12 V up to 240 V. The secondary current is 0.50 A. Find the primary current.
VpIp = VsIs, so Ip = 240 × 0.50/12 = 10 A.
A transformer takes 2.0 A at 230 V. The output is 11.5 V at 36 A. Find the efficiency.
Power in = 230 × 2.0 = 460 W. Power out = 11.5 × 36 = 414 W. Efficiency = 414/460 × 100% = 90%.
Section 8 of 9Key terms
| Term | Meaning |
|---|---|
| Turns ratio | Np : Ns, equal to the voltage ratio Vp : Vs. |
| Ideal transformer | One with 100% efficiency. |
| Efficiency | Useful power out divided by power in, as a percentage. |
| Rectifier | Circuit that converts a.c. to d.c. |
Section 9 of 9Exam technique
Marked practiceQuizzes for this lesson
Transformer Turns Ratio & Efficiency
Ratio: Vp / Vs = Np / Ns = Is / Ip
- Step-up reduces grid thermal loss (
P = I2R). - Laminated core prevents eddy currents.