Skip to content
Dabour HubLEARN · PRACTICE · EXPLORESign inStudent

5.2.2Additional lessons

Measuring Rates of Reaction — IB Chemistry SL Revision Notes & Topical Questions

5 min read 6 parts Lesson 67 of 98

📚 IB Chemistry SL Hub / Topical Revision
🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
0%read

Section 1 of 6Choosing a Property

The best method depends on the reaction being studied.

Principle
  • Principle Any property that changes steadily as reactants are converted into products can be monitored over time.
Gas evolved
  • Gas evolved Collect the gas in a syringe or over water and record the volume at regular time intervals.
Mass loss
  • Mass loss Where a gas escapes, a balance shows the mass falling, though light gases give small changes that are hard to measure.
Colour change
  • Colour change A colorimeter measures absorbance of a coloured reactant or product, which is linked to its concentration.

Section 2 of 6Methods

Methods
Gas syringe
  • Gas syringe Measures the volume of gas given off, as in the reaction of magnesium or calcium carbonate with acid.
Balance
  • Balance Measures decreasing mass of the flask and contents when a gas leaves, such as CO₂ from carbonates and acid.
Colorimetry
  • Colorimetry Measures how much light of a chosen wavelength is absorbed by a coloured solution as its concentration changes.
Conductivity and pH
  • Conductivity and pH Track changes in ion concentration or acidity during reactions that produce or use ions or H⁺.
ReactionMethod
Metal + acidGas syringe
Carbonate + acidMass loss or gas volume
Iodine formed or usedColorimetry
Ionic reactionConductivity

Section 3 of 6Collecting and Using Data

1
Set up the apparatus, and start timing at the moment the reactants are mixed.
2
Record the measurement at fixed intervals, such as every 10 s, until the readings stop changing.
3
Plot the property against time and draw a smooth curve.
4
Calculate the initial rate from the gradient of the tangent at time zero and compare it with rates under other conditions.
5
Repeat the experiment and calculate a mean to improve reliability.

Section 4 of 6Practical Considerations

Practical Considerations
Fair test
  • Fair test Change only one variable at a time and keep the temperature, volumes and concentrations of other factors the same.
Initial rates
  • Initial rates Comparing initial rates avoids the effects of changing concentration during the reaction.
Disappearing cross
  • Disappearing cross Timing how long a cross takes to vanish gives a simple measure, though it is subjective, and rate is taken as 1 ÷ time.
Sources of error
  • Sources of error Delay in starting the timer, gas escaping before the syringe is fitted and poor mixing all affect the data.

Section 5 of 6Worked Example

Question

  • In an experiment 24.0 cm³ of gas is collected in 40.0 s at a roughly constant rate.
  • Calculate the average rate in cm³ s⁻¹, and the rate if the volume after 80.0 s is 36.0 cm³ in total.

  1. Rate over first 40.0 s = 24.0 ÷ 40.0 = 0.600 cm³ s⁻¹.
  2. Rate over 80.0 s = 36.0 ÷ 80.0 = 0.450 cm³ s⁻¹.
  3. The average rate is lower over the longer period because the reaction slows as reactants are used.

Answer 0.600 cm³ s⁻¹ over 40 s and 0.450 cm³ s⁻¹ over 80 s

Section 6 of 6Exam Checklist & Tips

5.2.2 – Key Points for the Exam

  • Colorimeter An instrument measuring the absorbance of coloured solutions.
  • Gas syringe A syringe used to measure the volume of gas produced.
  • Tangent A line drawn touching a curve at one point, whose gradient gives the instantaneous rate.
  • Reliable data Results that are consistent when the experiment is repeated.

Common Mistakes

  • Starting the timer after mixing so that the first readings are missed.
  • Using the same volume and concentration for all runs and changing nothing, so the test shows no trend.
  • Choosing a method unsuitable for the reaction, such as mass loss for a reaction producing no gas.
  • Reading the rate from a graph without drawing a tangent.

Last updated:

\n