1.2.11Development of Practical Skills in Physics
Methods to Increase Accuracy
5 min read 9 parts Lesson 17 of 29 1 quiz
1.2.11 Methods to Increase Accuracy — OCR A Level Physics A notes: Select and justify practical techniques that reduce percentage uncertainty and systematic error in a measurement.Accuracy improves when you reduce the largest percentage uncertainty and remove systematic errors.
- Measure multiples
- Use larger distances or longer times
- Use a larger signal
- Choose the instrument with suitable resolution
- Repeat and average
- Use a graph
Section 1 of 9Where the improvement comes from
Accuracy improves when you reduce the largest percentage uncertainty and remove systematic errors.
The techniques below fall into three groups: make the measured quantity larger relative to its uncertainty, reduce random scatter, and eliminate systematic effects.
Section 2 of 9Make the measured quantity larger
Section 3 of 9Reduce random scatter
Section 4 of 9Remove systematic errors
Section 5 of 9Choosing and justifying a method
An examiner wants you to link the technique to the cause: “Timing 20 oscillations rather than one reduces the percentage uncertainty due to reaction time from 12% to 0.6%.” Always give an estimate of the improvement.
Section 6 of 9A short worked comparison of strategies
Suppose a student wants the speed of a trolley over a 1.00 m track.
Equally, remember that no technique can improve a result beyond the limit set by the weakest link. Once every percentage is below about 1%, further effort is better spent on checking that the method measures what it claims to measure, which is the idea of validity from the evaluation topic.
Section 7 of 9Worked examples
A student times one oscillation of a pendulum as 1.2 s with a reaction uncertainty of 0.2 s. They now time 25 oscillations and get 30.1 s with the same 0.2 s uncertainty. Compare the percentage uncertainties and find the new period.
Worked examplesSingle oscillation: 0.2/1.2 = 17%.25 oscillations: 0.2/30.1 = 0.66%.Period T = 30.1/25 = 1.20 s with the same 0.66% uncertainty, which is ±0.008 s. The improvement is a factor of about 25.A wire's diameter is 0.50 mm. Compare the percentage uncertainty using a rule (±0.5 mm) and a micrometer (±0.01 mm). The wire is also measured at 5 places along its length.
Rule: 0.5/0.50 = 100%, useless. Micrometer: 0.01/0.50 = 2%.
Averaging 5 readings at different positions reduces random variation (the wire may not be uniform) and the uncertainty in the mean falls to about 1%. Zero error should also be checked before use.
In a resistance experiment the current through a wire is 1.5 A and the wire warms up so R increases. Suggest and justify a change to improve accuracy.
The resistivity rises with temperature, so readings taken later are too high, a systematic error.
Use a lower current (for example 0.2 A) and switch off between readings, and keep a record of the temperature. The heating power I2R falls by a factor of (1.5/0.2)2 ≈ 56, so heating becomes negligible.
Section 8 of 9Key terms
| Term | Meaning |
|---|---|
| Percentage uncertainty | Uncertainty as a percentage of the measured value; used to compare measurements. |
| Fiducial marker | A fixed reference mark for judging the start or stop of a timing. |
| Calibration | Checking an instrument against a known standard. |
| Lagging | Insulating material that reduces heat loss. |
| Control variable | A quantity kept constant to make a test fair. |
| Best-fit line | A line through plotted data that averages out the scatter. |