Skip to content
Dabour HubLEARN · PRACTICE · EXPLORESign inStudent

3.16.3Organic Chemistry

Column Chromatography

5 min read 4 parts Lesson 54 of 55

0%read

Section 1 of 4Setting Up the Column

3.16.3 Column Chromatography
1
A glass tube is packed with a slurry of solid silica or alumina, which forms the stationary phase.
2
A small amount of the mixture dissolved in a little solvent is added carefully to the top of the column.
3
Solvent, the mobile phase or eluent, is added continuously at the top and flows down through the column under gravity.
4
Components move down at different rates, so they separate into bands in the column.
5
Fractions of the liquid leaving the bottom are collected in separate containers as each component emerges.

Section 2 of 4Why Components Separate

Adsorption
  • Polar components are held more strongly on a polar stationary phase and so move more slowly.
Solubility
  • Components that dissolve well in the eluent are carried along faster.
Retention time
  • The time a component takes to leave the column; strongly held components have long retention times.
Changing the eluent
  • Using a more polar solvent later speeds up strongly held components, a technique that improves separation.
Identification
  • Fractions can be analysed by TLC, or evaporated so that the pure product is recovered.

Section 3 of 4Comparison with TLC

Comparison with TLC
Scale
  • TLC is used to analyse tiny amounts, while column chromatography can separate larger amounts for purification.
Collection
  • In a column, each separated compound is collected in fractions; in TLC the spots stay on the plate.
Same principles
  • Both use the same stationary phase (silica or alumina) and both rely on adsorption and solubility.
Link
  • TLC is often used first to choose the solvent for a column.
FeatureTLCColumn
Purposeanalysisseparation and purification
Stationary phasesilica on platesilica in column
Mobile phasesolvent rising by capillary actionsolvent flowing down by gravity

Section 4 of 4Exam Checklist & Tips

3.16.3 – Key Points for the Exam

  • Eluent The solvent that carries the mixture through the column.
  • Retention time The time between injection or loading and the component leaving the column.
  • Fraction A portion of liquid collected from the bottom of the column.
  • Adsorption Attraction of a component to the surface of the stationary phase.

Common Mistakes

  • Letting the column run dry, which introduces air bubbles and ruins the separation.
  • Saying the least polar compound is retained longest on silica; polar compounds are held most strongly.
  • Confusing the mobile phase (moves) with the stationary phase (fixed in the column).
  • Using column chromatography only for analysis; its main use is purification.
\n