09 The ohmmeter
An ohmmeter measures an unknown resistance directly. Measuring a resistance by Ohm's law needs both an ammeter and a voltmeter (R = V / I). If the voltage is fixed and known, we can drop the voltmeter and mark the galvanometer scale in ohms instead of amperes.
It is a micro-ammeter (galvanometer) in series with a fixed resistance, a variable resistance (adjusted for zero) and a cell of constant emf (about 1.5 V), with two terminals between which the unknown resistance Rx is connected.
- Zero adjustment: with the terminals touching (Rx = 0, short circuit), the variable resistor is adjusted so that the pointer gives full-scale deflection: Rtotal = VB / Ig.
- With Rx inserted the current is I = VB/(Rtotal + Rx), which is smaller, so the deflection is smaller and the scale is calibrated directly in ohms.
- Features of the scale: zero ohms is at the full-scale end (the right) and infinite resistance at the left (open circuit) — opposite to the current scale; it is non-linear (the readings are spread out at the zero end and crowded at the high-resistance end).
- If Rx = Rtotal the current is half of FSD; if Rx = 2 Rtotal it is one-third FSD, etc. In general, I / Ig = Rtotal / (Rtotal + Rx).
- Reasons: the cell must have a constant emf (otherwise the calibration is wrong); the fixed resistor protects the meter and sets the calibration; the variable resistor is needed to bring the pointer exactly to the zero mark when the cell ages.
Example 9. An ohmmeter has a 1.5 V cell and a total internal resistance of 3000 Ω at FSD (500 μA). With an unknown resistor of 3000 Ω: I = 1.5/6000 = 250 μA = half of FSD. With 9000 Ω: I = 1.5/12000 = 125 μA = quarter of FSD.
Example 9a — a calibration table. An ohmmeter has a 1.5 V cell and FSD current 1 mA, so its total internal resistance is 1.5/0.001 = 1500 Ω. For different Rx:
- 1500 Ω
- 1.0 mA
- 1
- 2000 Ω
- 0.75 mA
- 3/4
- 3000 Ω
- 0.5 mA
- 1/2
- 6000 Ω
- 0.25 mA
- 1/4
- 15 000 Ω
- 0.1 mA
- 1/10
Example 9b — design. A milliammeter of resistance 20 Ω has FSD 10 mA. It is used as an ohmmeter with a 1.5 V cell of internal resistance 1 Ω. For FSD the total resistance must be 1.5/0.010 = 150 Ω, so the standard resistor needed (including the variable one) is 150 − 20 − 1 = 129 Ω. A reading of 6 mA means the total resistance is 1.5/0.006 = 250 Ω, so Rx = 250 − 150 = 100 Ω. With Rx = 600 Ω the current is 1.5/750 = 2 mA.