Section 1 of 5Structure
A transformer has two coils wound on a common iron core.
Primary coil
- Primary coil The input coil, connected to the a.c. supply, which creates a changing magnetic field in the iron core.
Secondary coil
- Secondary coil The output coil, in which the changing magnetic field induces an alternating potential difference.
Iron core
- Iron core Carries the magnetic field from the primary to the secondary, so that little of the field is lost as it would be in air.
Turns ratio
- Turns ratio The ratio of the numbers of turns on the two coils sets whether the output potential difference is larger or smaller than the input.
Section 2 of 5How a Transformer Works
Induction through the shared core transfers energy from the primary circuit to the secondary circuit.
1
An alternating current in the primary coil produces a constantly changing magnetic field in the iron core.
2
The changing magnetic field passes through the secondary coil and induces an alternating potential difference across it.
3
A transformer needs a changing input, because a steady d.c. field induces no potential difference in the secondary.
4
In a step-up transformer the secondary has more turns than the primary, so the output potential difference is larger than the input.
5
In a step-down transformer the secondary has fewer turns than the primary, so the output potential difference is smaller than the input.
Section 3 of 5Why Transformers Matter
Transformers allow electricity to be sent at high voltage and used at safe voltage.
Why Transformers Matter
Step-up use
- Step-up use Power stations use step-up transformers to raise the potential difference, which reduces the current and the energy lost in cables.
Step-down use
- Step-down use Step-down transformers near homes and factories lower the potential difference to a safe value for appliances.
Energy losses
- Energy losses Power lost in cables is given by I²R, so a smaller current from a higher voltage gives much lower losses.
Efficiency
- Efficiency Real transformers lose some energy as heat, so the output power is slightly less than the input power.
Section 4 of 5Worked Example
Question Explain why a transformer does not work when connected to a d.c. supply.
- A d.c. supply produces a steady current, which produces a steady magnetic field in the core.
- A steady magnetic field does not change, so no field lines cut the secondary coil.
- No potential difference is induced in the secondary coil, so the transformer produces no output.
Answer A steady d.c. field does not change, so it induces no potential difference in the secondary coil.
Section 5 of 5Exam Checklist & Tips
6.2.3 – Key Points for the Exam
- Transformer A device that changes the potential difference of an alternating supply using two coils linked by an iron core.
- Primary coil The input coil, which is connected to the alternating supply.
- Secondary coil The output coil, in which a potential difference is induced.
- Step-up transformer A transformer with more turns on the secondary than the primary, giving a larger output potential difference.
- Step-down transformer A transformer with fewer turns on the secondary than the primary, giving a smaller output potential difference.
Common Mistakes
- Saying a transformer changes the frequency; the frequency of the output is the same as the input.
- Connecting a transformer to a d.c. supply, which induces no potential difference in the secondary.
- Confusing step-up and step-down by counting the turns on the wrong coil.
- Stating that a transformer creates energy; it only transfers energy between two circuits.
Last updated:
Transformer Golden Equations
Physics Standard
Transformer Turns Ratio & Efficiency
Ratio: Vp / Vs = Np / Ns = Is / Ip
- Step-up reduces grid thermal loss (
P = I2R). - Laminated core prevents eddy currents.