Skip to content
Dabour HubLEARN · PRACTICE · EXPLORESign inStudent

3.2Unit 3. Practical Skills in Chemistry I

Inorganic & Organic Chemistry Core Practicals — IAL Edexcel Linear (Chemistry) Revision Notes & Topical Questions

5 min read 4 parts Lesson 2 of 2 1 quiz

🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key معادلة تفاعل تكوين الإستر (الأسترة) - Esterification Reaction EquationFast Exam Solution
R-COOH + R2-OH ⇌ (conc. H₂SO₄) R-COO-R2 + H₂O
Word Equation & Conditions: حمض كربوكسيلي + كحول (في وجود حمض الكبريتيك المركز كعامل حفاز ونازع للماء) ⇌ إستر + ماء
Location & Specifications: الكيمياء العضوية للثانوية العامة والتحصيلي و Edexcel Chemistry.
0%read
Lesson summary

3.2 Inorganic & Organic Chemistry Core Practicals — halogenoalkanes, chlorination, oxidation and ion tests — IAL EDEXCEL LINEAR (CHEMISTRY) notes: Describe and analyse Core Practicals 5 to 8: halogenoalkane hydrolysis, chlorination of 2-methylpropan-2-ol, oxidation of propan-1-ol…

  • Carbonate and hydrogencarbonate
  • Nucleophile
  • Distillation
  • Separating funnel
  • Drying agent
  • Qualitative analysis

Section 1 of 4More from the specification

Hydroxide
  • A compound containing the OH− ion, formed by Group I metals with water.
Pipette
  • Apparatus measuring a fixed volume such as 25.0 cm³.
Ionic equation
  • An equation showing only the ions that react.
Carbon dioxide
  • A gas that turns limewater cloudy.

Section 2 of 4Key terms

TermMeaning
HydrolysisBreaking a bond by reaction with water or hydroxide ions.
NucleophileA species with a lone pair that attacks an electron-deficient carbon.
RefluxHeating with a vertical condenser so vapour returns to the flask.
DistillationHeating a mixture so the most volatile component vaporises and is condensed and collected.
Separating funnelApparatus used to separate two immiscible liquid layers.
Drying agentAn anhydrous salt, e.g. MgSO4, that removes water from an organic liquid.
Qualitative analysisTests that identify which ions or functional groups are present.

Section 3 of 4Syllabus checklist

1
Hydrolysis with aqueous NaOH or KOH is very slow at room temperature, so the mixture is warmed.
2
The rate depends on the halogen.
  • The stronger the C-X bond, the slower the reaction: bond enthalpy C-F > C-Cl > C-Br > C-I.
  • Fluoroalkanes do not react; iodoalkanes react very quickly.
3
OH− is a better nucleophile than water because it carries a full negative charge, whereas oxygen in water has only a partial charge.
4
If NaOH(aq) is used, acidify with HNO3 before adding AgNO3.
1
Put equal volumes of ethanol and acidified silver nitrate into three test tubes in a 50 °C water bath.
2
Add a few drops of a chloroalkane, a bromoalkane and an iodoalkane, one to each tube.
3
Start the stopwatch immediately.
4
Time how long each precipitate takes to appear.
Core Practical 5: measuring the rate
Water acts as the nucleophile: R-X + H2O → R-OH + H+ + X−, then Ag+ + X− → AgX(s).
Ethanol is the common solvent so the halogenoalkane and aqueous silver nitrate mix.
HalogenoalkaneC-X bond enthalpy (kJ mol−1)PrecipitateRate
Chloroabout 346White AgClSlowest
Bromoabout 290Cream AgBrMedium
Iodoabout 228Yellow AgIFastest
  • Bond enthalpy, not polarity, controls the rate; tertiary halogenoalkanes react faster than primary ones.
  • Reaction(CH3)3COH + HCl → (CH3)3CCl + H2O at room temperature.
1
Place 8 cm3 of 2-methylpropan-2-ol in a separating funnel.
2
In a fume hood add 20 cm3 of concentrated HCl in 2–3 cm3 portions, releasing the pressure after each.
3
Leave for 20 minutes, gently shaking every 2 minutes.
4
Let the layers separate and run off the lower aqueous layer.
  • The chloroalkane forms the upper organic layer.
1
Add sodium hydrogencarbonate solution in small portions, shaking and releasing pressure, to remove acidic impurities.
2
Run off the aqueous layer.
3
Pour the organic layer into a dry conical flask and add two spatulas of anhydrous magnesium sulfate until the liquid is clear.
4
Decant into distillation apparatus.
5
Distil and collect the fraction at 47–53 °C.
  • A fume hood is essential because concentrated HCl is volatile and gives off hydrogen chloride gas;
    • the window must not be above the safety line.
  • Propan-1-ol oxidises to propanal (aldehyde) and then to propanoic acid.
1
Add 20 cm3 of acidified potassium dichromate(VI) to a pear-shaped flask and cool it in iced water.
2
Set up reflux apparatus and add anti-bumping granules.
3
Add 1 cm3 of propan-1-ol dropwise through the condenser.
4
Remove the ice bath and warm to room temperature.
5
Heat in a water bath or with an electric heater for 20 minutes.
6
Purify the product by distillation.
1
Distilling off the product at once gives propanal; heating under reflux with excess oxidant gives propanoic acid.
2
Boiling points: propanal 49 °C, propan-1-ol 97 °C, propanoic acid 141 °C.
3
Cr2O72− (orange) is reduced to Cr3+ (green).
4
Aldehydes give a silver mirror with Tollens' and a red precipitate with Fehling's; carboxylic acids fizz with NaHCO3.
1
Alcohols such as propan-1-ol, butan-1-ol and pentan-1-ol are flammable and harmful: keep them away from naked flames and use electric heating.
2
Avoid skin contact and breathing the vapour; use a fume cupboard for harmful alcohols.
3
Potassium dichromate is a strong oxidising agent and must be handled with care.
4
Mop up spillages straight away with plenty of water.
Core Practical 8: tests for ions
Dissolve a solid in deionised water before testing.
Ammonium
  • Ammonium warm with NaOH(aq) in a water bath; NH4+ + OH− → NH3 + H2O.
  • Damp red litmus paper turns blue in the NH3.
Carbonate and hydrogencarbonate
  • Carbonate and hydrogencarbonate add dilute HCl and pass the gas into limewater.
  • 2H+ + CO32− → CO2 + H2O and H+ + HCO3− → CO2 + H2O.
  • The limewater turns milky.
Sulfate
  • Sulfate acidify with dilute HCl, then add BaCl2(aq); a white precipitate of BaSO4 forms.
  • HCl first removes carbonates that would also give a precipitate.
Halides
  • Halides acidify with HNO3, add AgNO3 and test the precipitate with ammonia.
    • (white AgCl, cream AgBr, yellow AgI)
1
Dip a nichrome or platinum wire loop in concentrated acid and hold it in a blue flame until no colour shows.
2
Dip the loop in the solid sample.
3
Hold it at the edge of the blue flame without letting the wire glow red.
4
Record the colour (Li+ red, Na+ yellow, K+ lilac, Ca2+ orange-red).
  • Only one type of ion must be present, otherwise the colours mix.
Test forMethodPositive result
C=CShake with bromine waterOrange to colourless
-OH groupAdd PCl5Steamy fumes of HCl
Primary/secondary alcohol, aldehydeWarm with acidified K2Cr2O7Orange to green
Tertiary alcoholWarm with acidified K2Cr2O7No change

Section 4 of 4Exam technique

1
Forgetting to acidify with nitric acid before silver nitrate when NaOH was used — the hydroxide would give a false precipitate.
2
Using polarity to explain hydrolysis rate — the C-X bond enthalpy decides.
3
Heating organic liquids with a Bunsen burner — use an electric heater or water bath.
4
Not releasing pressure in the separating funnel — CO2 builds up when NaHCO3 meets acid.
5
Adding BaCl2 without acidifying first — carbonates also give a precipitate.

Last updated:

\n