Reactivity 3 — What are the mechanisms of chemical change?
Inquiry 2: Collecting and processing data — IB Chemistry SL Revision Notes & Topical Questions
10 min read 18 parts Lesson 10 of 12 Unit quiz
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
Lesson summary
Inquiry 2: Processing data, uncertainties and presenting results — IB CHEMISTRY SL notes: Process raw chemistry data into averages and rates, propagate uncertainties and present results with correct significant figures and graphs.Raw data table — the first table, containing only …
- Sufficient data
- Qualitative data
- Typical observations
- Use as evidence
- Issues during collection
- Anomalous result
Section 1 of 18Recording raw data
Raw data table
- Raw data table the first table, containing only direct measurements with no calculations.
Title
- Title specific to the experiment.
Headers
- Headers quantity, unit and uncertainty go in the column headings, not in each cell.
Precision
- Precision record to the precision of the instrument, with the same decimal places in a whole column.
Burette
- Burette readings to two decimal places, with the last digit 0 or 5, for example 24.50 cm3.
Balance
- Balance a balance reading to two decimal places gives masses such as 5.00 g, never 5 g.
Sufficient data
- Sufficient data at least five values of the independent variable, with at least three repeats of each.
Section 2 of 18Qualitative observations
Qualitative data
- Qualitative data non-numerical observations recorded alongside the numbers.
Typical observations
- Typical observations colour changes, effervescence, formation of a precipitate, soot during combustion and noticeable temperature changes.
Use as evidence
- Use as evidence observations help explain unexpected results and errors in the analysis and evaluation.
Issues during collection
- Issues during collection record problems such as a reaction that is too fast or slow, or a gradual endpoint.
Anomalous result
- Anomalous result record it, do a further trial to get concordant results, and do not erase it.
- Its exclusion is justified later.
Section 3 of 18Processing raw data
1Processed data
- Processed data new, clearly labelled table separate from the raw data.
2Working
- Working show one full set of working for each type of calculation, even if a spreadsheet is used.
3Units
- Units every calculated value has correct units, and a new quantity such as a rate needs derived units (for example s−1 or mol dm−3 s−1).
1
Average the repeat trials, leaving out any justified anomalous result.
2
Calculate the quantity of interest, for example rate = 1 / time.
3
Propagate the uncertainty through each calculation.
4
Round the final value to a suitable number of significant figures.
Section 4 of 18Averages in titrations
Concordant titres
- Concordant titres only titres within 0.10 cm3 of each other are averaged.
Rough titre
- Rough titre always excluded from the average.
Anomalous titres
- Anomalous titres excluded as well.
Titre
- Titre final burette reading minus initial burette reading.
Dilution
- Dilution if the sample was diluted, multiply the calculated concentration by the dilution factor.
Section 5 of 18Propagating uncertainty
1Addition or subtraction
- Addition or subtraction add the absolute uncertainties.
- A titre uses two burette readings, so the uncertainty is 0.05 + 0.05 = 0.10 cm3.
2Multiplication or division
- Multiplication or division add the percentage uncertainties.
- For n = C × V, the percentage uncertainty in n is that in C plus that in V.
3Reciprocal
- Reciprocal for rate = 1 / t, the percentage uncertainty in the rate equals the percentage uncertainty in time.
4Powers (HL)
- Powers (HL) multiply the percentage uncertainty by the power.
5Final uncertainty
- Final uncertainty quote it to one significant figure and give the result to the same number of decimal places.
6Sample calculation
- Sample calculation show the propagation for the main processed result.
Section 6 of 18Significant figures in processed results
1Rule
- Rule the final answer has the same number of significant figures as the least precise data used.
2Calculator display
- Calculator display never write down the full display.
3Constants
- Constants a constant such as the Avogadro constant is used with its defined number of significant figures and does not limit precision.
4Intermediate values
- Intermediate values keep the calculator value until the final answer to avoid rounding errors.
Section 7 of 18Presenting results as a graph
Presenting results as a graph
Title
- Title describes the relationship investigated.
Axes
- Axes independent variable on x, dependent variable on y, with quantities and units.
Scale
- Scale appropriate, linear, and using at least half of the space.
Points
- Points clearly plotted, usually as a small x or a point in a circle.
Line of best fit
- Line of best fit a smooth line or curve showing the overall trend, with about equal numbers of points on each side.
Gradient
- Gradient can represent a key value, for example the rate constant k from a rate against concentration graph for a first-order reaction.
Intercept
- Intercept the value of the dependent variable when the independent variable is zero.
Area under a curve
- Area under a curve a total quantity such as the number of particles in a Maxwell–Boltzmann curve.
Error bars
- Error bars their size shows precision, and large bars suggest significant random error.
Section 8 of 18More from the specification
1Quantitative Data Collection and Experimental Accuracy
- In scientific chemistry inquiry, gathering sufficient quantitative raw data with high measurement accuracy is essential to answer a focused research question reliably.
2Disappearing Cross Experiment with Sodium Thiosulfate
- In reaction kinetics investigations, the reaction between sodium thiosulfate and hydrochloric acid produces a cloudy sulfur precipitate;
- timing how long it takes for a black cross to disappear allows quantitative rate analysis.
3Acid-Base Titration of Commercial Vinegar
- Determining the concentration of ethanoic acid in household vinegar involves volumetric titration with standard sodium hydroxide solution, calculating mean concordant titres for rigorous data interpretation.
4Scientific Interpretation of Experimental Results
- Interpreting results requires analyzing graphs, identifying anomalous data points, calculating percentage errors,
- and formulating evidence-based scientific conclusions that evaluate methodological validity.
5Vinegar
- An ethanoic acid solution of about 5%.
6Accuracy
- Closeness of a result to the true value.
Section 9 of 18Interpreting a graph
1Aim
- Aim find what the results tell you so that the research question can be answered.
2Two steps
- Two steps first describe the trend, then explain it with chemical principles.
3Describing
- Describing use terms such as linear positive correlation, inversely proportional, exponential increase and the rate plateaus.
4Explaining
- Explaining link the trend to theory such as collision theory or intermolecular forces;
- this is the most important part.
5Use data
- Use data a description should quote values from the data.
Section 10 of 18Explaining the effect of temperature on rate
1Trend
- Trend rate increases non-linearly with temperature, rising at an accelerating pace.
2Higher kinetic energy
- Higher kinetic energy raising temperature increases the average kinetic energy of the particles.
3More frequent collisions
- More frequent collisions the particles move faster.
4More successful collisions
- More successful collisions a much greater proportion of particles have at least the activation energy, and this is the main reason for the steep rise.
Section 11 of 18Anomalous results
Definition
- Definition an anomalous result is a point that clearly does not fit the overall trend.
Showing it
- Showing it highlight it on the graph.
Justifying it
- Justifying it link it to a likely experimental error, such as a delay in starting a stopwatch.
Handling
- Handling it is excluded from the average and the graph with the reason stated.
Section 12 of 18Qualitative and quantitative data together
Qualitative evidence
- Qualitative evidence observations help explain quantitative results.
Soot
- Soot black soot on a calorimeter shows incomplete combustion, which releases less energy.
Effect
- Effect an enthalpy of combustion lower in magnitude than the data booklet value can be explained by this observation.
Section 13 of 18Accuracy and precision
| Idea | Meaning | Affected by |
|---|---|---|
| Accuracy | How close the final result is to the accepted or true value | Systematic errors |
| Precision | How close repeat measurements are to each other | Random errors |
1Accuracy needs a literature value
- Accuracy needs a literature value it can only be commented on when one exists.
2Precise but inaccurate
- Precise but inaccurate a small spread of repeats does not prove accuracy;
- a systematic error gives precise but wrong results.
Section 14 of 18Reliability and validity
Reliability
- Reliability the consistency of results; several concordant repeats make results reliable.
Validity
- Validity relates to the method;
- results are valid if it was a fair test with significant variables controlled.
Spread of repeats
- Spread of repeats the range or half-range gives a practical estimate of random uncertainty.
Reporting
- Reporting quote the final value with its uncertainty and say whether the spread of repeats supports it.
Cautious conclusions
- Cautious conclusions a large percentage uncertainty tells the reader the conclusion must be cautious.
Section 15 of 18Random and systematic error
| Error type | Effect on data | How to reduce it |
|---|---|---|
| Random | Scatter around the true value; affects precision | Repeat trials and average; use a better instrument |
| Systematic | Shifts all results the same way; affects accuracy | Calibrate the instrument, change the method, correct for heat loss |
Section 16 of 18More from the specification
1
Data collection with a burette
- During acid-base titration experiments, initial and final burette readings are recorded to two decimal places, calculating the titre as the difference between readings.
2
Concordant titres and data processing
- Processing experimental data involves identifying concordant titre values to calculate a mean titre, discarding non-concordant outliers.
- (readings within 0.10 cm3 of each other)
3
Calculating unknown concentrations
- Processed stoichiometric data allows determination of the unknown concentration of analyte solutions using balanced reaction ratios (n = c * V) with correct scientific units (mol dm-3.
4
Evaluating independent variables in kinetics
- In chemical kinetics, systematically varying the independent reactant concentration while measuring reaction times produces processed rate data expressed in scientific notation.
5
Data collection with a burette
- During acid-base titration experiments, initial and final burette readings are recorded to two decimal places, calculating the titre as the difference between readings.
6
Concordant titres and data processing
- Processing experimental data involves identifying concordant titre values to calculate a mean titre, discarding non-concordant outliers.
- (readings within 0.10 cm3 of each other)
7
Calculating unknown concentrations
- Processed stoichiometric data allows determination of the unknown concentration of analyte solutions using balanced reaction ratios (n = c * V) with correct scientific units (mol dm-3.What the symbols mean: c = concentration (mol dm−3) · n = amount (mol) · V = volume (dm3; divide cm3 by 1000)
8
Evaluating independent variables in kinetics
- In chemical kinetics, systematically varying the independent reactant concentration while measuring reaction times produces processed rate data expressed in scientific notation.
9
Independent variable
- The variable that is changed.
10
Significant figures
- The digits in a value that are reliable and carry meaning.
11
Dependent variable
- The variable that is measured.
12
Concentration
- Moles ÷ volume in dm³, or g/dm³.
13
Burette
- Apparatus delivering a variable volume accurately, 0-50 cm³.
14
Vinegar
- An ethanoic acid solution of about 5%.
Section 17 of 18Key terms
| Term | Meaning |
|---|---|
| Raw data | Measurements exactly as recorded from the instrument. |
| Processed data | Raw data after calculation, such as averages and rates. |
| Propagated uncertainty | Uncertainty in a calculated result found by combining the uncertainties of the measured values. |
| Significant figures | Meaningful digits in a number, set by the least precise measurement. |
| Concordant titres | Titres within 0.10 cm3 of each other. |
| Error bar | A bar on a graph point showing its uncertainty. |
| Anomalous result | A value clearly outside the pattern of the other repeats. |
| Intercept | The point where a line crosses an axis. |
| Term | Meaning |
|---|---|
| Accuracy | How close a result is to the accepted value. |
| Precision | How close repeated measurements are to each other. |
| Reliability | How consistent repeat results are. |
| Validity | Whether the method measures what it is meant to, with variables controlled. |
| Collision theory | Reactions occur when particles collide with enough energy and correct orientation. |
| Activation energy | The minimum energy particles need for a successful collision. |
| Anomalous result | A data point that does not fit the overall trend. |
Section 18 of 18Exam technique
1
Quoting final answers with more significant figures than the least precise data allow.
2
Adding absolute uncertainties when multiplying — percentage uncertainties are added for multiplication and division.
3
Omitting units for calculated quantities such as rate.
4
Removing an anomalous result without stating the reason.
5
Recording raw data to the wrong number of decimal places for the instrument.
1
Commenting on accuracy without a literature value to compare with.
2
Confusing precision with accuracy — precise results can still be inaccurate if there is a systematic error.
3
Explaining the temperature effect only by more frequent collisions — the larger proportion of particles with at least the activation energy is the major factor.
4
Describing a graph without quoting any data from it.
Last updated:
\n