Section 1 of 5Key Equations

Turns ratio
- For an ideal transformer, Vp ÷ Vs = Np ÷ Ns, where V is the voltage and N is the number of turns on each coil.
Power equation
- For an ideal (100% efficient) transformer the input power equals the output power, so Vp × Ip = Vs × Is.
Units
- Potential difference is measured in volts (V), current in amperes (A) and power in watts (W).
Rearranging
- The turns-ratio equation can be rearranged to find any unknown, for example Vs = Vp × Ns ÷ Np.
Section 2 of 5Calculation Steps
1
Identify which coil is the primary and which is the secondary, and write down the known values with their units.
2
Use the turns ratio to find the unknown voltage or the unknown number of turns.
3
Use Vp × Ip = Vs × Is to find the unknown current when a current is required.
4
Check that the result is consistent with the type of transformer, such as a step-down transformer having a lower secondary voltage.
Section 3 of 5Common Scenarios
Common Scenarios
Step-down
- A step-down transformer has more primary turns than secondary turns, so the output voltage is lower and the output current is higher.
Efficiency
- Real transformers lose some energy as heat, so the output power is slightly lower than the input power.
Current on the step-down side
- The current rises on the step-down side, because the same power is delivered at a lower voltage.
Checking answers
- For an ideal transformer, the input and output power should be equal, which is a useful check on any answer.
Section 4 of 5Worked Example
Question
- A transformer has 2000 turns on the primary coil and 100 turns on the secondary coil.
- The primary is connected to a 230 V supply and draws 0.20 A.
- Assuming 100% efficiency, calculate (a) the secondary voltage and (b) the secondary current.
- (a) Vs = Vp × Ns ÷ Np = 230 V × 100 ÷ 2000.
- Vs = 23 000 ÷ 2000 = 11.5 V.
- (b) Input power = Vp × Ip = 230 V × 0.20 A = 46 W.
- Is = power ÷ Vs = 46 W ÷ 11.5 V = 4.0 A.
Answer
- The secondary voltage is 11.5 V and the secondary current is 4.0 A;
- this is a step-down transformer.
Section 5 of 5Exam Checklist & Tips
6.2.3 – Key Points for the Exam
- Turns ratio The ratio of the number of turns on the secondary coil to the number on the primary coil.
- Ideal transformer A transformer with no energy losses, so input power equals output power.
- Efficiency The percentage of input energy or power that is transferred to useful output.
- Input power The power supplied to the primary coil.
- Output power The power delivered by the secondary coil.
Common Mistakes
- Placing the turns ratio the wrong way up, so the voltage ratio is reversed.
- Forgetting that the current ratio is inverse to the voltage ratio, so current changes in the opposite direction.
- Using the lengths of the coils instead of their numbers of turns.
- Giving answers without units, such as 11.5 instead of 11.5 V.
Last updated:
Transformer Golden Equations
Physics Standard
Transformer Turns Ratio & Efficiency
Ratio: Vp / Vs = Np / Ns = Is / Ip
- Step-up reduces grid thermal loss (
P = I2R). - Laminated core prevents eddy currents.