Tools and Inquiry — IB Physics skills

T.1.2 Measuring Variables in Physics — IB Physics HL Revision Notes & Topical Questions

5 min read 9 parts Lesson 3 of 22 1 quiz

📚 IB Physics HL Hub / Topical Revision
🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
0%read
Lesson summary

T.1.2 Measuring Variables in Physics — IB PHYSICS SL notes: Choose and use instruments to measure mass, time, length, volume, temperature, force, current, voltage, angle, sound and light correctly.Choose an instrument whose range and resolution match the measurement — to give val…

  • A ruler measures a few centimetres to the nearest millimetre
  • The instrument must not disturb the system
  • Liquid thermometer
  • Digital temperature probe
  • Stir liquids and keep the bulb away from the walls
  • Potential difference

Part 1 of 7Choosing instruments

Choosing instruments
Choose an instrument whose range and resolution match the measurement
  • Choose an instrument whose range and resolution match the measurement to give valid, high-quality data.
A ruler measures a few centimetres to the nearest millimetre
  • A ruler measures a few centimetres to the nearest millimetre a micrometer suits very small sizes and a tape measure larger distances.
Using the largest possible reading reduces percentage uncertainty.
  • A 0–10 V meter reading 8.0 V ± 0.1 V has 1.3% uncertainty; reading 0.8 V gives 12.5%.
The instrument must not disturb the system
  • The instrument must not disturb the system and its sensitivity must match the changes of interest.

Part 2 of 7Mass, time and length

Mass
  • Mass a digital balance to two decimal places; tare it first and record in kilograms.
Time
  • Time a stopwatch or stop-clock; the unit is the second.
    • (1 minute = 60 s)
  • Human reaction time matters for intervals under a second — use light gates or video instead.
Length
  • Length standard unit is the metre; a ruler reads to 1 mm, read perpendicular to avoid parallax.
  • A micrometer reads to 0.01 mm: use the ratchet and subtract any zero error.
  • Measure a stack of sheets and divide to reduce percentage uncertainty for thin objects.
Volume
  • Volume a measuring cylinder; 1 mL of water = 1 cm3.
  • The change in level gives the volume of an irregular solid.

Part 3 of 7Temperature

Temperature
Liquid thermometer
  • Liquid thermometer uses expansion of alcohol or mercury in a capillary tube.
  • Reads to the nearest 1 °C or 0.5 °C; simple, robust and cheap.
  • It equilibrates slowly and is less precise than digital options.
Digital temperature probe
  • Digital temperature probe uses thermistors or thermocouples.
  • Reads to ±0.1 °C or better with fast, real-time readings.
  • Suits data logging and remote or automated experiments, and reduces human error.
Stir liquids and keep the bulb away from the walls
  • Stir liquids and keep the bulb away from the walls and read at eye level.

Part 4 of 7Force, current and potential difference

Force, current and potential difference
Force
  • Force measured directly with a force meter (spring balance) in newtons.
Current
  • Current an ammeter connected in series with the part measured.
Potential difference
  • Potential difference a voltmeter connected in parallel across the component.
Check meters for zero error before use
  • Check meters for zero error before use subtract any zero reading from all measurements.
Analogue meters have a needle and scale and suffer parallax error
  • Analogue meters have a needle and scale and suffer parallax error read perpendicular to the scale.
Digital meters read small values (mA, µA, mV) and are more precise
  • Digital meters read small values (mA, µA, mV) and are more precise but the display may flicker, so a judgement is needed.
Typical analogue ranges
  • 0.1–1.0 A and 1.0–5.0 A for ammeters; 0.1–1.0 V or 0–5.0 V for voltmeters.

Part 5 of 7Angle, sound and light

Angle
  • Angle a protractor with precision ±0.5°.
  • Align the baseline carefully and read at eye level.
  • Use a consistent reference point, such as measuring from a drawn normal to the centre of the ray.
Sound intensity
  • Sound intensity a sound level meter with precision about ±0.1 dB.
  • Hold at a fixed distance, because intensity falls with distance (inverse square law).
  • Avoid background noise.
Light intensity
  • Light intensity a light meter, photodiode or lux meter, precision about ±1 W m-2.
  • Keep the detector perpendicular to the source and shield from stray light.
  • Ambient light affects results, so use a dark room where possible.

Part 6 of 7Reducing measurement errors

Parallax
  • Parallax view the scale at right angles; a mirror behind the scale helps.
Zero error
  • Zero error check the reading with no input and subtract it.
Calibration
  • Calibration compare with a known standard, such as ice at 0 °C and boiling water.
Reaction time
  • Reaction time time longer intervals or use automated timing.
Environment
  • Environment shield from draughts, vibration and heat sources when precision matters.

Part 7 of 7More from the specification

1Laboratory Safety with Pressure Equipment
  • Experiments involving gas pressure and closed thermal vessels require pressure relief valves, protective shielding,
  • and heat-resistant glass to prevent explosive failure.
2Safe Use and Disposal of Batteries
  • Chemical battery cells must be monitored against accidental short-circuit heating, stored safely,
  • and disposed of in designated recycling channels to eliminate toxic heavy metal hazards.
3Apparatus Handling and Risk Assessment
  • Proper laboratory investigations demand hazard evaluation of high voltages, sharp glassware,
  • and corrosive reagents, accompanied by personal protective apparatus.
4Ethical Issues in Scientific Experimentation
  • Researchers must adhere to ethical standards by recording raw data honestly, avoiding fabrication,
  • and ensuring environmental and biological safety.
5Battery
  • Two or more cells joined together.
6Apparatus
  • The equipment needed to carry out an experiment.
7Pressure
  • Force per unit area, P = F/A.
    What the symbols mean: p = pressure (Pa = N m−2) · F = force acting at right angles to the surface (N) · A = area (m2)
8Electron diffraction
  • The spreading of an electron beam by atomic gaps in a crystal, giving ring patterns that show wave behaviour.

Key terms

TermMeaning
ResolutionSmallest change an instrument can detect or display.
Parallax errorApparent shift in a reading from viewing a scale at an angle.
Zero errorNon-zero reading when the true value is zero.
CalibrationChecking an instrument against a known standard.
TareSetting a balance to zero before weighing.
Reaction timeDelay of about 0.2 s in a human starting or stopping a timer.

Avoid these mistakes

1
Reading a scale from an angle, causing parallax error.
2
Ignoring zero error in a micrometer, meter or balance rather than correcting it.
3
Using a stopwatch for a very short event — reaction time dominates.
4
Connecting a voltmeter in series or an ammeter in parallel.
5
Using a coarse instrument whose resolution is too large for the quantity.