5.2.2Additional lessons
Measuring Rates of Reaction — IB Chemistry HL Revision Notes & Topical Questions
5 min read 5 parts Lesson 97 of 172
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
Section 1 of 5Choosing a Method
The best method depends on which property of the mixture changes measurably as the reaction proceeds.
Gas volume
- Gas volume Collect gas in a gas syringe or inverted measuring cylinder, and record volume at regular time intervals.
Mass loss
- Mass loss Place the reaction flask on a balance and record the mass falling as a gas escapes.
Colour change
- Colour change A colorimeter measures absorbance of a coloured species, which is proportional to its concentration.
Conductivity or pH
- Conductivity or pH Use a probe if the reaction changes the number or type of ions or the acidity of the solution.
Section 2 of 5Collecting Reliable Data
1
Start the timer at the moment the final reactant is added and mix the solutions immediately.
2
Record the property at regular time intervals, with more frequent readings at the start when change is fastest.
3
Control other variables such as temperature, volume and concentration unless they are being varied.
4
Repeat the experiment and calculate a mean to improve reliability.
5
Plot the data and draw a smooth curve, then use tangents to find the rate at selected times.
Section 3 of 5Alternative Approaches
Alternative Approaches
Initial rate method
- Initial rate method Measure the time for a fixed small change and compare rates at several starting concentrations.
Clock reaction
- Clock reaction Time how long a sudden colour change takes to appear; a shorter time indicates a faster rate.
Sampling
- Sampling Remove samples at intervals and quench the reaction before titrating to find the concentration.
Limitations
- Limitations Gas can dissolve or leak, and mass loss is hard to detect for light gases like hydrogen.
Section 4 of 5Worked Example
Question
- A gas syringe collects 24.0 cm³ of carbon dioxide in 40.0 s.
- Calculate the average rate of gas production and state one improvement to the method.
- Average rate = volume ÷ time = 24.0 ÷ 40.0 = 0.600 cm³ s⁻¹.
- Improvementtake readings at shorter intervals and repeat the experiment to find a mean.
- Another improvementkeep the temperature constant using a water bath.
Answer 0.600 cm³ s⁻¹
Section 5 of 5Exam Checklist & Tips
5.2.2 – Key Points for the Exam
- Colorimeter An instrument that measures absorbance of light by a coloured solution.
- Quenching Stopping a reaction suddenly so that a sample can be analysed.
- Clock reaction A reaction in which a sudden visible change marks a set amount of reaction.
- Reliability How closely repeated measurements agree with each other.
Common Mistakes
- Starting the timer before all reactants have been mixed.
- Using too few readings in the early stage when the rate changes quickly.
- Using a mass-loss method for a gas of very low molar mass.
- Failing to keep temperature constant when comparing different concentrations.
Last updated:
\n