The Hydrogen Electrode — IB Chemistry HL Revision Notes & Topical Questions

5 min read 5 parts Lesson 142 of 172

📚 IB Chemistry HL Hub / Topical Revision
🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
0%read

Section 1 of 5Standard Hydrogen Electrode

The hydrogen electrode is the reference against which all other electrode potentials are measured.

Construction
  • Construction Hydrogen gas is bubbled over a platinum electrode coated with platinum black, which dips into an acid solution.
Conditions
  • Conditions The acid has [H⁺] = 1.00 mol dm⁻³, the gas pressure is 100 kPa, and the temperature is 298 K.
Half-equation
  • Half-equation 2H⁺(aq) + 2e⁻ ⇌ H₂(g), and its standard electrode potential is defined as exactly 0.00 V.
Platinum role
  • Platinum role Platinum is inert and catalyses the reaction, while its rough surface adsorbs hydrogen gas.

Section 2 of 5Measuring Electrode Potentials

1
Connect the half-cell under test to the hydrogen electrode with a salt bridge and a high-resistance voltmeter.
2
Make sure all solutions are at 1.00 mol dm⁻³ and the temperature is 298 K, so that the potential is a standard value.
3
Read the voltage, which is the standard electrode potential E° of the half-cell because the reference is zero.
4
If the half-cell is the positive terminal its E° is positive, and if it is the negative terminal E° is negative.
5
Tabulate each value as a reduction half-equation so that the series can be compared directly.

Section 3 of 5Using the Values

Using the Values
Positive E°
  • Positive E° The oxidised form is easily reduced, so it is a strong oxidising agent, for example Cl₂ with E° = +1.36 V.
Negative E°
  • Negative E° The oxidised form is hard to reduce, so the metal is easily oxidised, for example Zn²⁺/Zn with E° = −0.76 V.
Ions in solution
  • Ions in solution When no metal is present, such as Fe³⁺/Fe²⁺, an inert platinum wire is used to carry electrons.
Reference limits
  • Reference limits Because the electrode needs hydrogen gas, other practical reference electrodes are often used.
Half-cellE° / V
Zn²⁺/Zn−0.76
H⁺/H₂0.00
Cu²⁺/Cu+0.34
Ag⁺/Ag+0.80

Section 4 of 5Worked Example

Question

  • A standard zinc half-cell is connected to a standard hydrogen electrode, and zinc is the negative terminal with a cell voltage of 0.76 V.
  • State the standard electrode potential of Zn²⁺/Zn.

  1. The hydrogen electrode has E° = 0.00 V, so the whole cell voltage is due to the zinc half-cell.
  2. Zinc is the negative terminal, so the zinc half-cell is less able to attract electrons than the hydrogen electrode.
  3. Therefore the reduction potential of the zinc half-cell is negative.

Answer E°(Zn²⁺/Zn) = −0.76 V

Section 5 of 5Exam Checklist & Tips

6.2.11 – Key Points for the Exam

  • Standard hydrogen electrode The reference half-cell with an electrode potential defined as 0.00 V.
  • Standard electrode potential The voltage of a half-cell measured against the SHE under standard conditions.
  • Standard conditions 1.00 mol dm⁻³ solutions, 100 kPa gas pressure and 298 K.
  • Inert electrode An electrode such as platinum that conducts but does not react.

Common Mistakes

  • Writing the electrode potential for an oxidation equation without changing its sign.
  • Claiming the SHE potential is measured, when it is defined to be zero.
  • Forgetting that 1.00 mol dm⁻³ H⁺ and 100 kPa H₂ are both required.