Skip to content
Dabour HubLEARN · PRACTICE · EXPLORESign inStudent

7.1.2Additional lessons

Measuring Variables in Chemistry — IB Chemistry HL Revision Notes & Topical Questions

5 min read 6 parts Lesson 159 of 172

📚 IB Chemistry HL Hub / Topical Revision
🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
0%read

Section 1 of 6Measuring Amounts and Volumes

Quantities such as mass and volume are the starting point for nearly every calculation in a practical.

Mass
  • Mass A balance gives mass in grams;
    • a digital reading carries an uncertainty equal to its last displayed digit, such as ±0.001 g.
Volume of liquids
  • Volume of liquids Pipettes and volumetric flasks deliver one fixed volume very precisely,
    • while burettes and measuring cylinders let you choose a volume.
Gas volume
  • Gas volume Gas syringes and inverted measuring cylinders over water collect gas, and the volume read must be corrected if the gas is soluble.
Choice of tool
  • Choice of tool Pick the instrument whose smallest division is small compared with the quantity measured,
    • because this keeps the percentage uncertainty low.
InstrumentTypical useUsual uncertainty
Digital balanceWeighing solids± last digit
BuretteTitre volumes±0.05 cm³ per reading
Volumetric pipetteFixed 25.00 cm³Marked on the glassware
Measuring cylinderApproximate volumes± half smallest division

Section 2 of 6Measuring Temperature, Time and pH

Measuring Temperature, Time and pH
Temperature
  • Temperature Thermometers and temperature probes record energy changes,
    • and a temperature change involves two readings,
    • so its uncertainty is the sum of both.
Time
  • Time A stopwatch has a small instrument uncertainty, but human reaction time of about 0.2 s is usually the larger source of error.
pH
  • pH A pH meter must be calibrated with buffer solutions first, and universal indicator only gives an approximate whole-number pH.
Conductivity
  • Conductivity A conductivity probe follows the concentration of ions, which makes it useful for reactions that produce or remove ions.

Section 3 of 6Reading Instruments Correctly

1
Look at the scale and identify the smallest division before taking any reading from an analogue instrument.
2
Read liquid volumes at eye level with the bottom of the meniscus on the mark to avoid parallax error.
3
Record every digit shown on a digital display, including trailing zeros, because they show the precision of the instrument.
4
Quote the uncertainty as half the smallest division for analogue devices and as the last digit for digital devices.
5
Repeat the measurement where possible and compare readings to judge how reliable the instrument and method are.

Section 4 of 6Uncertainty and Precision

Absolute uncertainty
  • Absolute uncertainty This is the size of the possible error in the same unit as the reading, for example ±0.05 cm³.
Percentage uncertainty
  • Percentage uncertainty Divide the absolute uncertainty by the measured value and multiply by 100 to compare how reliable different measurements are.
Precision
  • Precision Precision describes how closely repeat readings agree, and it is set by the instrument and the technique together.
Accuracy
  • Accuracy Accuracy describes how close a result is to the accepted value, which a precise instrument cannot guarantee if it is miscalibrated.

Section 5 of 6Worked Example

Question

  • A titre is found from two burette readings, 2.10 cm³ and 24.60 cm³, each with uncertainty ±0.05 cm³.
  • Find the titre and its percentage uncertainty.

  1. Titre = 24.60 − 2.10 = 22.50 cm³.
  2. Absolute uncertainty = 0.05 + 0.05 = ±0.10 cm³ because two readings were subtracted.
  3. Percentage uncertainty = 0.10 ÷ 22.50 × 100 = 0.44 %.

Answer Titre = 22.50 ± 0.10 cm³ (0.44 %)

Section 6 of 6Exam Checklist & Tips

7.1.2 – Key Points for the Exam

  • Meniscus
    • The curved surface of a liquid in a tube;
      • read the lowest point for most solutions.
  • Calibration Checking an instrument against a known standard so that its readings can be trusted.
  • Absolute uncertainty The possible error in a reading, quoted with the same unit as the reading.
  • Parallax error A false reading caused by viewing a scale from an angle rather than at eye level.
  • Precision How closely repeated measurements agree with one another.

Common Mistakes

  • Quoting the uncertainty of a titre as ±0.05 cm³ when it comes from two readings and should be ±0.10 cm³.
  • Dropping the final zero in a digital reading, which hides the true precision of the instrument.
  • Using a measuring cylinder when a burette or pipette is needed for a quantitative result.
  • Confusing accuracy with precision; the two describe different qualities of a measurement.

Last updated:

\n