Applying Technology to Collect Data in Chemistry — IB Chemistry HL Revision Notes & Topical Questions

5 min read 6 parts Lesson 161 of 172

📚 IB Chemistry HL Hub / Topical Revision
🩺
100% Curriculum Specification Match Lesson Doctor Verified
The only platform with 100% curriculum specification match and verified interactive question banks.
Curriculum Equation Key قوانين الرقم الهيدروجيني والاتزان الأيوني - pH & Acid-Base Equilibrium FormulasFast Exam Solution
pH = -log[H⁺] | pOH = -log[OH⁻] | pH + pOH = 14 | [H⁺][OH⁻] = 10⁻¹⁴
Word Equation & Conditions: الرقم الهيدروجيني = -لوغاريتم تركيز أيون الهيدروجين | pH + pOH = 14
Location & Specifications: الاتزان الأيوني، كيمياء 3 ثانوي، التحصيلي، و AP Chemistry.
0%read

Section 1 of 6Sensors and Data Loggers

Technology lets experimenters collect larger and more precise data sets than manual reading.

Sensor
  • Sensor A probe converts a physical quantity such as temperature, pH, gas pressure or conductivity into an electrical signal.
Data logger
  • Data logger The signal is recorded automatically at set time intervals and stored for later analysis on a computer.
Advantages
  • Advantages Readings are frequent, free from human reaction time and can follow very fast or very slow changes with little effort.
Limitations
  • Limitations Probes need calibration, have a limited range and response time, and may drift, so results still need critical checking.

Section 2 of 6Spectroscopic Methods

Spectroscopic Methods
Colorimetry
  • Colorimetry A coloured solution absorbs light, and the absorbance is proportional to concentration within a limited range.
Calibration curve
  • Calibration curve Absorbance is measured for solutions of known concentration, and an unknown is read from the resulting graph.
Filter choice
  • Filter choice The filter or wavelength is chosen to be absorbed strongly by the solution, which is usually the colour complementary to the solution.
Blank
  • Blank A cuvette containing only solvent sets zero absorbance and removes the effect of the container.

Section 3 of 6Planning Automated Data Collection

1
Decide which variable the sensor will measure and check that its range includes the expected values.
2
Calibrate the probe with standards, such as buffers of known pH for a pH probe.
3
Set a logging interval short enough to capture the fastest change and long enough to avoid unmanageable data.
4
Start logging before the reaction begins so that the starting baseline is also recorded.
5
Save the file, check for gaps or spikes, and export the data for processing.

Section 4 of 6Other Technologies

Digital imaging
  • Digital imaging Photographs and video record colour changes or precipitation, so timings can be checked afterwards frame by frame.
Gas sensors
  • Gas sensors Pressure sensors in a sealed flask follow gas production and give a smooth curve rather than a few spot readings.
Conductivity probes
  • Conductivity probes These follow reactions where the number of ions changes, such as the neutralisation of an acid with a base.
Remote data
  • Remote data Online databases and shared files let results be compared with accepted values quickly.

Section 5 of 6Worked Example

Question

  • A calibration line for a coloured complex follows A = 840 × c, where c is in mol dm⁻³.
  • A sample gives an absorbance of 0.42.
  • Find its concentration.

  1. Rearrange the calibration equation to c = A ÷ 840.
  2. c = 0.42 ÷ 840.
  3. c = 5.0 × 10⁻⁴ mol dm⁻³.

Answer c = 5.0 × 10⁻⁴ mol dm⁻³

Section 6 of 6Exam Checklist & Tips

7.2.1 – Key Points for the Exam

  • Data logger A device that records sensor readings automatically over time.
  • Absorbance A measure of how much light a solution takes in at a chosen wavelength.
  • Calibration curve A graph of a measured signal against known concentrations, used to find unknown values.
  • Sensor A probe that converts a physical or chemical quantity into an electrical signal.
  • Blank A reference sample containing everything except the substance being measured.

Common Mistakes

  • Assuming that a digital reading is automatically accurate, when an uncalibrated probe can give consistently wrong values.
  • Using a filter of the same colour as the solution, which gives very little absorbance.
  • Reading a concentration from a calibration curve far outside the range of the standards.
  • Starting the logger after the reaction has begun, which loses the first and most important readings.