Text lesson

7.4.6 Root-Mean-Square Current and Potential Difference

7.4.6 Root-Mean-Square Current and Potential Difference — Edexcel A Level Physics 9PH0 notes: Calculate rms and peak values for alternating supplies and use them to find average power.

1Why we need an effective value2What the symbols mean:3What the symbols mean:4Root-mean-square (rms)
Why we need an effective value
Why we need an effective value
An alternating voltage averages to zero over a cycle

but a heater still gets hot.
1 / 4Next ▶
What the symbols mean:
1

The heating effect depends on the
2

square
3

of the current (P = I
4

2
5

R),
6

and the square is never negative.What the symbols mean: P = power (W) · I = current (A) · R = resistance (Ω)
◀ Previous2 / 4Next ▶
What the symbols mean:
What the symbols mean:
So we define an effective value by the d.c. value that would deliver the same average power to the same resistor.
◀ Previous3 / 4Next ▶
Sinusoidal a.c. voltage-time trace with peak voltage and r.m.s. level marked
Root-mean-square (rms)
Sinusoidal a.c. voltage-time trace with peak voltage and r.m.s. level marked" loading= - Dr Khaled Dabour Academy⤢ Enlarge
Root-mean-square (rms)
This is the
root-mean-square (rms)
value.
◀ Previous4 / 4
Definition and calculation
1

To find the rms value of a varying current: take the square of the instantaneous values, find the mean of those squares over a cycle

then take the root. For a sinusoid, the mean of sin2 over a cycle is ½, so
2

Irms = I0/√2 Vrms = V0/√2
3

That means Irms ≈ 0.707 I0. This relation applies only to sinusoidal signals. For a square wave that swings between +V0 and −V0, the rms value is simply V0

because the square is constant.
4

Ammeters and voltmeters set to a.c. and the values printed on appliances (for example 230 V) normally give rms values. The peak of 230 V mains is 230 × √2 ≈ 325 V.
Power in an a.c. circuit
1

The instantaneous power in a resistor is P = I2R = I02R sin2ωt. Its graph is always positive and oscillates between zero and a peak value P0 = I0V0, at twice the supply frequency. The mean value is half the peak:
2

Pmean = IrmsVrms = Irms2R = Vrms2/R = ½I0V0
3

Take care: the peak power is double the average power for a sinusoidal supply. When a question refers to the power rating of an appliance, this is the mean power and uses rms values.
1Using rms values on graphs2Using rms values on graphs3Using rms values on graphs
Using rms values on graphs
Using rms values on graphs
On a voltage-time graph, the rms value is not read from the trace directly

read the peak and divide by √2. If the trace is a power-time graph, the average power lies halfway between zero and the maximum, and the graph is symmetric about this mean.
1 / 3Next ▶
Using rms values on graphs
1

For a non-sinusoidal waveform, such as a half-wave rectified signal, you cannot use √2

instead compute the mean square over the full cycle.
2

For a half-wave rectified sine wave, only half the cycle contributes

so the mean square is V
3

0
4

2
5

/4 and V
6

rms
◀ Previous2 / 3Next ▶
Using rms values on graphs
Using rms values on graphs
= V
/2.
◀ Previous3 / 3
1Links and applications2Links and applications3Links and applications
Links and applications
Links and applications
Power stations transmit electrical energy at very high voltage so that the rms current is small, reducing the power wasted as I2R in the cables.
1 / 3Next ▶
Links and applications
1

Transformers step voltage up and down, and the ratio of rms voltages equals the turns ratio.
2

Insulation must withstand the
3

peak
4

voltage, not the rms voltage

so the safety rating of capacitors and cables is based on V
5

0
6

.
◀ Previous2 / 3Next ▶
Links and applications
Links and applications
Together with Faraday’s law and the properties of alternating signals, this topic completes the picture of how electrical power is generated, transmitted and used.
◀ Previous3 / 3
1Worked reasoning with graphs2Worked reasoning with graphs3Worked reasoning with graphs
Worked reasoning with graphs
Worked reasoning with graphs
A common exam task is to start from a graph of current against time and deduce the power.
1 / 3Next ▶
Worked reasoning with graphs
1

Read the peak current from the vertical scale, divide by √2 to find I
2

rms
3

,
4

and then multiply by the rms voltage or square it and multiply by the resistance.
5

If you are given a graph of power against time, the mean power is the level halfway between the minimum (zero) and the maximum

it is not the value at the peaks.
6

It also helps to remember where the factor of one half comes from.
◀ Previous2 / 3Next ▶
Worked reasoning with graphs
Worked reasoning with graphs
The squared sine wave sin
2
oscillates between 0 and 1 and is symmetric about 0.5.
So the mean of the squared quantity is half its maximum, and taking the square root gives the factor 1/√2 for voltage or current.
For energy: a heater that transfers 2.0 kW on average for 3 hours uses 6.0 kWh, regardless of the peak instantaneous power.
◀ Previous3 / 3
1Worked examples2Worked examples
Worked examples
Worked examples
Worked example 1. The mains supply is 230 V rms. Find the peak voltage and peak-to-peak voltage.
V0 = √2 × Vrms = 1.414 × 230 = 325 V.
Peak-to-peak = 2 × 325 = 650 V.
Worked example 2. A heater is rated 2.0 kW at 230 V rms. Calculate the rms current, the resistance and the peak power.
Irms = P/Vrms = 2000/230 = 8.7 A.
R = Vrms/Irms = 230⁄8.70 = 26 Ω.
1 / 2Next ▶
Worked examples
1

Peak power = 2 × mean power = 4.0 kW.
2

Worked example 3. A sinusoidal supply of peak voltage 5.0 V is connected across a 10 Ω resistor. Find the mean power dissipated.
3

Vrms = 5.0/√2 = 3.54 V.
4

P = Vrms2/R = 12.5/10 = 1.25 W. (Check: ½V02/R = ½ × 25⁄10 = 1.25 W.)
◀ Previous2 / 2
Key terms
Term Meaning
Root-mean-square value The value of a steady d.c. that would dissipate the same mean power in a resistor as the a.c.: the square root of the mean of the squares.
Peak value The maximum magnitude of an alternating quantity.
Mean power Average rate of energy transfer over a full cycle; for a sinusoid, half the peak power.
Peak power The maximum instantaneous power, I0V0 for a resistor.
Rectified wave An a.c. signal altered so that current flows in only one direction.
Mains supply Domestic a.c. supply, rated 230 V rms at 50 Hz in the UK.
1Avoid these mistakes2Avoid these mistakes3Avoid these mistakes
Avoid these mistakes
1Avoid this
Applying VAvoid this
rmsAvoid this
= VAvoid this
0Avoid this
/√2 to waveforms that are not sinusoidal, such as square or rectified waves.Avoid this
1 / 3Next ▶
Avoid these mistakes
2Avoid this
Using the peak voltage in P = VAvoid this
/R and giving this as the average power. It gives the peak power; the mean is half.Avoid this
3Avoid this
Stating that the rms voltage is the average voltage. The average of a sinusoid over a cycle is zero.Avoid this
4Avoid this
◀ Previous2 / 3Next ▶
Avoid these mistakes
Dividing by 2 instead of √2 when converting between peak and rms.Avoid this
5Avoid this
Reading appliance ratings (230 V, 2 kW) as peak values when they are rms and mean power.Avoid this
◀ Previous3 / 3
Accepted payment methods