Curriculum
Course: College Physics for AP Courses 2e
Login

Curriculum

College Physics for AP Courses 2e

Unit 8: Linear Momentum and Collisions

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 9: Statics and Torque

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 10: Rotational Motion and Angular Momentum

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 11: Fluid Statics

0/40 Dr Dabour Hub Science Diagram and Course Material

Unit 12: Fluid Dynamics and Its Biological and Medical Applications

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 13: Temperature, Kinetic Theory, and the Gas Laws

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 14: Heat and Heat Transfer Methods

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 15: Thermodynamics

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 16: Oscillatory Motion and Waves

0/48 Dr Dabour Hub Science Diagram and Course Material

Unit 17: Physics of Hearing

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 18: Electric Charge and Electric Field

0/36 Dr Dabour Hub Science Diagram and Course Material

Unit 19: Electric Potential and Electric Field

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 20: Electric Current, Resistance, and Ohm's Law

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 21: Circuits and DC Instruments

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 22: Magnetism

0/48 Dr Dabour Hub Science Diagram and Course Material

Unit 23: Electromagnetic Induction, AC Circuits, and Electrical Technologies

0/52 Dr Dabour Hub Science Diagram and Course Material

Unit 25: Geometric Optics

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 26: Vision and Optical Instruments

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 27: Wave Optics

0/40 Dr Dabour Hub Science Diagram and Course Material

Unit 28: Special Relativity

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 29: Quantum Physics

0/35 Dr Dabour Hub Science Diagram and Course Material
Text lesson

20.5 Alternating Current versus Direct Current

20.5 Alternating Current versus Direct Current — COLLEGE PHYSICS FOR AP COURSES notes: You will be able to explain how AC and DC differ, calculate rms voltage, current and average power, and explain why AC is used for power transmission.

1Direct current and alternating current2Direct current and alternating current
Direct current and alternating current
Direct current and alternating current
Most of the circuits we have studied so far used batteries

which provide a constant voltage. Once the current is established in such a circuit, it is also constant. Direct current (DC) is the flow of electric charge in only one direction. It is the steady state of a constant-voltage circuit.
Many practical applications, however, use a voltage that changes with time. Alternating current (AC) is the flow of electric charge that periodically reverses direction.
When the source voltage varies periodically, and especially when it varies sinusoidally, the circuit is called an alternating current circuit.
The commercial and residential power that supplies homes and businesses is an example.
The frequency and peak voltage of AC supplies differ greatly from one country to another.
The graphs below compare the two cases. In part (a), the DC voltage and current stay constant in time. In part (b), the voltage and current for 60-Hz AC power are sinusoidal. In a simple resistive circuit they rise and fall together

so they are in phase.
1 / 2Next ▶
Two graphs: a flat line for constant DC voltage and current, and sine waves for 60-Hz AC voltage and current that rise and fall together. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
Direct current and alternating current
◀ Previous2 / 2
1AC voltage source and the current in a resistor2AC voltage source and the current in a resistor
AC voltage source and the current in a resistor
AC voltage source and the current in a resistor
Consider a simple circuit with an AC voltage source connected to a resistor.
The voltage between the terminals fluctuates sinusoidally with time.
The voltage at time t is given by v(t) = V0 sin(2πft),

where v is the instantaneous voltage in volts (V), V0 is the peak voltage in volts (V), f is the frequency in hertz (Hz),and t is the time in seconds (s).
In this simple resistive circuit the resistance R is the same at all times

so Ohm’s law gives the current as i(t) = I0 sin(2πft)where i is the instantaneous current in amperes (A) and I0 = V0/R is the peak current in amperes (A). The current, like the voltage, reverses direction and passes through zero twice in each cycle.
1 / 2Next ▶
A resistor across an AC source, and a graph of the sinusoidal voltage that reaches its positive and negative peaks twice per cycle. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
AC voltage source and the current in a resistor
AC voltage source and the current in a resistor: A resistor across an AC source, and a graph of the sinusoidal voltage that reaches its positive and negative peaks twice per cycle." loading= - Dr Khaled Dabour Academy⤢ Enlarge
AC voltage source and the current in a resistor
The current in the resistor alternates in step with the driving voltage.
A fluorescent lamp connected to 60-Hz power therefore brightens and dims 120 times per second,

because the current passes through zero twice in each cycle.
The flicker is too fast for the eye to see directly,

but when you wave your hand between your face and the lamp you see a stroboscopic effect,which is evidence of AC.
◀ Previous2 / 2
1Power in an AC circuit2Power in an AC circuit
Power in an AC circuit
1

The instantaneous power delivered to the resistor is P = iv. Because the voltage and current are in phase, the power varies as P(t) = I0V0 sin2(2πft). This product is never negative, and it swings between zero and the maximum value I0V0 twice in every cycle.
2

In practice we are usually interested in the average power, not its rapid fluctuations.
3

For example, a 60-W light bulb in a desk lamp has an average power consumption of 60 W.
4

Averaging the sine-squared function over a full cycle gives the average power Pave = ½I0V0

where Pave is in watts (W).
5

The average power is half of the maximum power.
1 / 2Next ▶
Power in an AC circuit against time: it rises to a maximum of I0 times V0, falls to zero, and its average value is half that maximum. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
Power in an AC circuit
◀ Previous2 / 2
Rms voltage and current
Rms voltage and current
Because the average of a sine wave over a full cycle is zero, we use the root mean square (rms) values instead. To find an rms value, square the quantity, take its average

and then take the square root. The rms current Irms and rms voltage Vrms are
Irms = I0/√2 and Vrms = V0/√2, both in SI units of amperes (A) and volts (V) respectively.
It is standard practice to quote rms values rather than peak values.
Household electricity of “120 V AC” means that Vrms is 120 V

so the peak voltage is about 170 V.
A 10-A circuit breaker interrupts a sustained current greater than 10 A

which is an rms value.
You can think of rms and average values as the equivalent DC values for a simple resistive circuit.
Ohm’s law and power for AC
1

When dealing with AC, Ohm’s law and the power equations have the same form as for DC, provided that rms or average values are used. For AC, Ohm’s law is written Vrms = IrmsR

where R is the resistance in ohms (Ω).
2

The expressions for AC power are Pave = IrmsVrms = Irms2R = Vrms2/R

where Pave is the average power in watts (W), and Irms and Vrms are in amperes (A) and volts (V).
1Making connections: take-home experiment on electrical energ2Making connections: take-home experiment on electrical energ3Making connections: take-home experiment on electrical energ
Making connections: take-home experiment on electrical energy use
Making connections: take-home experiment on electrical energy use
Make a list of the power ratings of appliances at home or in your room.
A toaster has a higher rating than a digital clock because it converts much more electrical energy to heat per second.
You can estimate the energy an appliance uses in a day by multiplying its power by its time of use.
Some appliances only list their operating current.
If the household voltage is 120 V, the power is the current multiplied by 120 V.
A second activity is to add up the total wattage of the lights in a school washroom.
1 / 3Next ▶
Making connections: take-home experiment on electrical energy use
Making connections: take-home experiment on electrical energy use
If each long fluorescent tube is rated at 32 W and the lights were left on from 6 p.m.
Friday until 8 a.m.
Monday, they stayed on for 62 hours.
The energy for each tube is 32 W × 62 h = 1984 Wh, or about 2.0 kWh.
Multiplying by the number of tubes and by the price per kWh gives the cost of the oversight,
and repeating this for every weekend of a year gives the yearly cost.
◀ Previous2 / 3Next ▶
Making connections: take-home experiment on electrical energy use
1

This also explains the earlier discussion on bulbs.
2

Compact fluorescent lamps (CFLs) cost more at first

but they use much less electrical energyso they are cheaper over their lifetime.
3

A business would also pay for the labor of replacing incandescent bulbs more often, a cost that was not included in that comparison.
◀ Previous3 / 3
1Why AC is used for power distribution2Why AC is used for power distribution
Why AC is used for power distribution
1

Most large power-distribution systems use AC. Economies of scale make it cheaper to build a few very large power plants than many small ones

so electricity must be carried over long distances. Energy lost in the transmission lines must therefore be kept as small as possible.
2

The power loss in a line is Ploss = I2R

where I is the current in amperes (A) and R is the resistance of the line in ohms (Ω).
3

For a given power, the current is I = P/V.
4

Raising the voltage lowers the current, and because the loss depends on the square of the current, the loss falls very sharply.
5

High voltages can therefore be transmitted with much smaller power losses than low voltages.
6

Power is sent at high voltages, often 330,000 V or more, and transformers reduce the voltage to safe values at the point of use.
1 / 2Next ▶
An electrical substation with large transformers that step up the voltage for long-distance transmission, using high-voltage insulators on the tall posts. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
Why AC is used for power distribution
Why AC is used for power distribution: An electrical substation with large transformers that step up the voltage for long-distance transmission, using high-voltage insulators on the tall posts." loading= - Dr Khaled Dabour Academy⤢ Enlarge
Why AC is used for power distribution
A transformer is a passive device that changes the voltage of an AC supply.
It is much easier to increase and decrease AC voltages than DC voltages

which is the crucial reason AC is used in most large distribution systems.
◀ Previous2 / 2
The war of the currents
1

It is widely believed that high voltages are always more dangerous than low ones

but some high voltages, such as those from ordinary static electricity, can be harmless. Hazard depends on more than voltage alone. It is less widely known that AC shocks are often more harmful than similar DC shocks.
2

In the late 1800s Thomas Edison believed AC shocks were more harmful, and he set up a DC power-distribution system in New York City. Edison, George Westinghouse and Nikola Tesla had bitter disagreements

because Westinghouse and Tesla advocated AC in early power systems. AC prevailed mainly because of transformers and the lower power losses that come with high-voltage transmission.
PhET explorations: Generator
PhET explorations: Generator
The PhET Generator simulation lets you make electricity with a bar magnet. Moving a magnet near a coil produces a voltage that can light a bulb. You can explore how magnets make the bulb light and see the physics behind it.
1Example 20.9: Peak voltage and power for AC2Example 20.10: Power losses are less for high-voltage transm3Example 20.10: Power losses are less for high-voltage transm
Example 20.9: Peak voltage and power for AC
Example 20.9: Peak voltage and power for AC
Problem: (a) What is the peak voltage of 120-V AC power? (b) What is the peak power consumption of a 60.0-W AC light bulb?
Strategy: The rms voltage is 120 V and the average power is 60.0 W. We use Vrms = V0/√2 for the voltage and Pave = ½I0V0 for the power.
Solution for (a): V0 = √2 × Vrms = 1.414 × 120 V = 169.7 V

which rounds to 170 V.
Discussion for (a): The AC voltage swings from +170 V to −170 V and back 60 times each second. An equivalent DC voltage is a constant 120 V.
Solution for (b): The peak power is I0V0. Since Pave = ½I0V0, we have I0V0 = 2Pave = 2 × 60.0 W = 120 W.
Discussion for (b): The power swings from zero to 120 W 120 times per second, twice in each cycle, and its average is 60 W.
1 / 3Next ▶
Example 20.10: Power losses are less for high-voltage transmission
1

Problem: (a) What current is needed to transmit 100 MW of power at 200 kV? (b) What power is dissipated by transmission lines with a resistance of 1.00 Ω? (c) What percentage of the power is lost in the lines?
2

Strategy: The transmitted power is P = 100 MW, the voltage is V = 200 kV, and the line resistance is R = 1.00 Ω. We find the current from I = P/V

then the power lost from Ploss = I2Rand then the ratio of the lost power to the transmitted power.
3

Solution for (a): I = (1.00 × 108 W)/(2.00 × 105 V) = 500 A.
4

Solution for (b): Ploss = (500 A)2 × 1.00 Ω = 2.50 × 105 W = 250 kW.
5

Solution for (c): Percent loss = (250 kW / 100 MW) × 100 = 0.250%.
6

Discussion: A loss of one-quarter of a percent is acceptable.
◀ Previous2 / 3Next ▶
Example 20.10: Power losses are less for high-voltage transmission
1

If the same 100 MW were sent at 25 kV, the current would be 4000 A and the line loss would be (4000 A)2 × 1.00 Ω = 16.0 MW, or 16.0% of the power.
2

The lower the voltage, the larger the current and the larger the loss in fixed-resistance lines.
3

Lower-resistance lines are possible

but they require larger and more expensive wires.
◀ Previous3 / 3
Key terms
Term Meaning
Direct current (DC) A flow of electric charge that stays in one direction, produced by a constant-voltage source.
Alternating current (AC) A flow of electric charge that periodically reverses direction, produced by a time-varying voltage source.
Frequency f The number of complete cycles of an AC voltage per second, measured in hertz (Hz).
Peak voltage V0 The largest value of an AC voltage, measured in volts (V).
Peak current I0 The largest value of an AC current, measured in amperes (A).
In phase Describes a voltage and current that rise and fall together and reach their peaks at the same times, as in a simple resistive circuit.
Instantaneous power P The power at a particular moment, equal to the product of current and voltage, measured in watts (W).
Average power Pave The power averaged over a full cycle, equal to half of the maximum power for a resistive AC circuit, measured in watts (W).
Root mean square (rms) A kind of average found by squaring a quantity, averaging it, and taking the square root. It gives the equivalent DC value of an AC quantity.
Rms voltage Vrms The peak voltage divided by √2, measured in volts (V).
Rms current Irms The peak current divided by √2, measured in amperes (A).
Transformer A device that changes the voltage of an AC supply, stepping it up or down.
Power loss Ploss Energy converted to heat in transmission lines, equal to I2R and measured in watts (W).
1Avoid these mistakes2Avoid these mistakes3Avoid these mistakes4Avoid these mistakes5Avoid these mistakes
Avoid these mistakes
1Avoid this
Using the peak voltage in an AC power formula when the question gives the rms voltage. Convert first:Avoid this
VAvoid this
0Avoid this
= √2Avoid this
rmsAvoid this
1 / 5Next ▶
Avoid these mistakes
.Avoid this
2Avoid this
Assuming that the average value of a sine wave is useful for AC power.Avoid this
Over a full cycle the average voltage and current are zero, so rms values must be used.Avoid this
3Avoid this
Confusing average power with peak power. For a resistive AC circuit the peak power is twice the average power.Avoid this
◀ Previous2 / 5Next ▶
Avoid these mistakes
4Avoid this
Thinking that the voltage must be lowered to reduce transmission losses.Avoid this
Raising the voltage lowers the current, and the loss I2R falls with the square of the current.Avoid this
5Avoid this
Forgetting to square the current inAvoid this
PAvoid this
◀ Previous3 / 5Next ▶
Avoid these mistakes
lossAvoid this
=Avoid this
IAvoid this
RAvoid this
, or to convert MW and kV to W and V before calculating.Avoid this
6Avoid this
◀ Previous4 / 5Next ▶
Avoid these mistakes
Believing that a flicker at 120 Hz means the frequency is 120 Hz.Avoid this
A 60-Hz supply makes a lamp brighten and dim twice per cycle, which is 120 times per second.Avoid this