Curriculum
Course: College Physics for AP Courses 2e
Login

Curriculum

College Physics for AP Courses 2e

Unit 8: Linear Momentum and Collisions

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 9: Statics and Torque

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 10: Rotational Motion and Angular Momentum

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 11: Fluid Statics

0/40 Dr Dabour Hub Science Diagram and Course Material

Unit 12: Fluid Dynamics and Its Biological and Medical Applications

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 13: Temperature, Kinetic Theory, and the Gas Laws

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 14: Heat and Heat Transfer Methods

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 15: Thermodynamics

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 16: Oscillatory Motion and Waves

0/48 Dr Dabour Hub Science Diagram and Course Material

Unit 17: Physics of Hearing

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 18: Electric Charge and Electric Field

0/36 Dr Dabour Hub Science Diagram and Course Material

Unit 19: Electric Potential and Electric Field

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 20: Electric Current, Resistance, and Ohm's Law

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 21: Circuits and DC Instruments

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 22: Magnetism

0/48 Dr Dabour Hub Science Diagram and Course Material

Unit 23: Electromagnetic Induction, AC Circuits, and Electrical Technologies

0/52 Dr Dabour Hub Science Diagram and Course Material

Unit 25: Geometric Optics

0/32 Dr Dabour Hub Science Diagram and Course Material

Unit 26: Vision and Optical Instruments

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 27: Wave Optics

0/40 Dr Dabour Hub Science Diagram and Course Material

Unit 28: Special Relativity

0/28 Dr Dabour Hub Science Diagram and Course Material

Unit 29: Quantum Physics

0/35 Dr Dabour Hub Science Diagram and Course Material
Text lesson

21.5 Null Measurements

21.5 Null Measurements — COLLEGE PHYSICS FOR AP COURSES notes: You will be able to explain why a null measurement is more accurate than a standard voltmeter or ammeter, and use a potentiometer or a Wheatstone bridge to find an unknown emf or an unknown resistance.

1Why measurements alter circuits2Why measurements alter circuits3Why measurements alter circuits4Why measurements alter circuits5Why measurements alter circuits6Why measurements alter circuits
Why measurements alter circuits
Why measurements alter circuits
Every measurement made with a meter changes the circuit being measured to some degree.
1 / 6Next ▶
Why measurements alter circuits
1

A voltmeter must draw a small current to operate

so part of the current that would normally flow through a component is diverted into the meter.
2

An ammeter has its own resistance

so when it is placed in a branch it increases the total resistance and reduces the current.
3

In both cases the reading differs from the value the circuit had before the meter was connected,
4

and this difference is an uncertainty in the measurement.
5

For large, macroscopic circuits this alteration can usually be made negligibly small by choosing a voltmeter with a very high resistance or an ammeter with a very low resistance.
6

It can never be made exactly zero with ordinary meters.
◀ Previous2 / 6Next ▶
Why measurements alter circuits
Why measurements alter circuits
For submicroscopic systems such as atoms and nuclei, measuring disturbs the system in a way that cannot be made arbitrarily small.
This sets a fundamental limit on what can be known about such systems,
and it is studied in more detail in the discussion of the Heisenberg uncertainty principle in quantum mechanics.
A null measurement avoids the problem by drawing no current from the circuit at all.
1
Instead of letting current flow through the detecting device, the measurement adjusts a known quantity until the detector reads exactly zero.
◀ Previous3 / 6Next ▶
Why measurements alter circuits
Why measurements alter circuits
2
At that point the detector carries no current

so the circuit under test is left unchanged, and the result depends only on the known reference.
3
Digital meters that use solid-state electronics and null techniques can reach accuracies far better than analog instruments.
4
Null methods are more complex to set up than a simple voltmeter or ammeter,
◀ Previous4 / 6Next ▶
An analog voltmeter across a battery draws a small current, so it reads a terminal voltage slightly below the emf. The right circuit shows the meter as a galvanometer in series with a large resistor. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
Why measurements alter circuits
Why measurements alter circuits: An analog voltmeter across a battery draws a small current, so it reads a terminal voltage slightly below the emf. The right circuit shows the meter as a galvanometer in series with a large resistor." loading= - Dr Khaled Dabour Academy⤢ Enlarge
1

and they still have limits to their precision,
2

but they are among the most accurate ways to measure voltage and resistance.
3

The figure below compares a battery measured by an analog voltmeter on the left with the equivalent circuit on the right

where the meter is a galvanometer with its internal resistance in series with a large resistor. Because the meter needs a current to operate, the battery supplies a small current I, and the reading is not the emf.
4

A real battery has an internal resistance r.
5

The voltage across its terminals, called the terminal voltage V, is related to the emf ε by V = ε − Ir,
6

where V and ε are in volts, I is the current in amperes and r is the internal resistance in ohms.
◀ Previous5 / 6Next ▶
Why measurements alter circuits
1

When current flows, the terminal voltage is smaller than the emf by the amount Ir.
2

Since r is not known precisely, the emf cannot be calculated precisely from the terminal voltage.
3

The emf could be measured directly if the current were zero

because then V would equal ε.
4

5
5

A standard voltmeter needs a current to operate

so another technique is needed.
◀ Previous6 / 6
1The Potentiometer2The Potentiometer3The Potentiometer4The Potentiometer5The Potentiometer6The Potentiometer7The Potentiometer8The Potentiometer9The Potentiometer10The Potentiometer
The Potentiometer
The Potentiometer
A potentiometer is a null device for measuring potentials

which are voltages.
1 / 10Next ▶
The Potentiometer
1

It uses a voltage source connected across a long, uniform wire, often a resistance wire

so that a constant current I flows through the wire.
2

Because of this current there is a steady potential drop along the wire,
3

so a variable potential can be picked out by making a contact point at different places along the wire.
4

To measure an unknown emf, εx, connect it in series with a galvanometer, with its polarity opposing the source that drives the wire.
5

1
6

Move the contact point along the wire until the galvanometer reads zero.
◀ Previous2 / 10Next ▶
The Potentiometer
The Potentiometer
2
At this balance point the potential drop along the section of wire up to the contact equals ε
x
.
3
Write this as ε
◀ Previous3 / 10Next ▶
The Potentiometer
The Potentiometer
= IR
where R
is the resistance of the wire section up to the contact point.
4
No current flows through the galvanometer

so no current flows through the unknown source either.
5
◀ Previous4 / 10Next ▶
The Potentiometer
1

Its emf is therefore sensed directly, and its internal resistance does not affect the reading.
2

Next, replace the unknown with a standard emf εs, a source whose value is known very precisely.
3

Move the contact point until the galvanometer again reads zero.
4

Now ε
5

s
6

is the resistance of the wire section up to the new contact point.
◀ Previous5 / 10Next ▶
The Potentiometer
1

The current I through the long wire is the same in both measurements,
2

because the galvanometer carries no current in either balance and the driving source is unchanged.
3

Dividing one equation by the other cancels I

which gives ε
4

/ε
5

= R
6

/R
◀ Previous6 / 10Next ▶
The Potentiometer
The Potentiometer
Solving for the unknown gives ε
= ε
(R
).
◀ Previous7 / 10Next ▶
A potentiometer: a steady current through a long wire creates a potential drop, and the contact point is moved until the galvanometer reads zero. The unknown emf is then the standard emf multiplied by a ratio of wire resistances. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
The Potentiometer
The Potentiometer: A potentiometer: a steady current through a long wire creates a potential drop, and the contact point is moved until the galvanometer reads zero. The unknown emf is then the standard emf multiplied by a ratio of wire resistances." loading= - Dr Khaled Dabour Academy⤢ Enlarge
1

The wire is long and uniform

so its resistance is proportional to its length.
2

The ratio of resistances R
3

is therefore the same as the ratio of the lengths of wire that balance the two emfs, L
4

/L
5

The unknown emf is ε
6

(L
◀ Previous8 / 10Next ▶
The Potentiometer
The Potentiometer
Every quantity on the right-hand side is known or measured

so ε
can be calculated.
The uncertainty is much smaller than when a voltmeter is used directly

but it is not zero.
There is always some uncertainty in the length ratio and in the value of the standard emf.
6
It is also impossible to tell exactly when the galvanometer reads zero,
◀ Previous9 / 10Next ▶
The Potentiometer
The Potentiometer
and this judgement error affects both balance points and may slightly change the current I.
◀ Previous10 / 10
1Resistance measurements with standard meters2Resistance measurements with standard meters
Two ways to measure resistance with ordinary meters: an ammeter with an assumed constant source voltage, and a voltmeter that measures the actual terminal voltage. In both cases the resistance is found as voltage divided by current. Image: OpenStax, College Physics for AP Courses 2e, CC BY 4.0.
Resistance measurements with standard meters
Resistance measurements with standard meters: Two ways to measure resistance with ordinary meters: an ammeter with an assumed constant source voltage, and a voltmeter that measures the actual terminal voltage. In both cases the resistance is found as voltage divided by current." loading= - Dr Khaled Dabour Academy⤢ Enlarge
1

Many instruments called ohmmeters claim to measure resistance

but most of them work indirectly. An ohmmeter applies a voltage to a resistor, measures the current through it, and calculates the resistance from Ohm’s law, R = V/I. The display shows this calculated value.
2

Two arrangements of an ammeter and a voltmeter can do the same job. In the first, the source voltage is assumed to be constant, and the ammeter reading gives the resistance. In the second, the terminal voltage is measured directly with a voltmeter

which is better because the terminal voltage changes as the current changes.
3

Both arrangements are limited in accuracy.
1 / 2Next ▶
Resistance measurements with standard meters
1

Each meter alters the voltage applied to the resistor or the current that flows through it

so the calculated resistance is never exact.
2

A meter that gives an accurate current reading when the current is large may give an inaccurate voltage reading in the same circuit,
3

and the opposite can also be true.
4

Null measurements avoid this difficulty because they draw no current from the circuit under test.
◀ Previous2 / 2
1The Wheatstone bridge2The Wheatstone bridge3The Wheatstone bridge4The Wheatstone bridge5The Wheatstone bridge6The Wheatstone bridge7The Wheatstone bridge8The Wheatstone bridge9The Wheatstone bridge
The Wheatstone bridge
The Wheatstone bridge
The Wheatstone bridge is a null device for calculating an unknown resistance by balancing potential drops in a circuit.
1 / 9Next ▶
The Wheatstone bridge
1

It has two branches connected across the same source.
2

The galvanometer connects one point in the first branch to one point in the second branch

so that it forms a bridge between the two branches.
3

A variety of bridge devices use this same idea to make null measurements.
4

In the arrangement used here, one branch contains two resistors, R1 from point a to point b and R2 from point b to point c.
5

1
6

The second branch contains a variable resistor R
◀ Previous2 / 9Next ▶
The Wheatstone bridge
The Wheatstone bridge
3
from point a to point d and the unknown resistance R
x
from point d to point c.
2
The resistors R
◀ Previous3 / 9Next ▶
The Wheatstone bridge
The Wheatstone bridge
and R
are precisely known, and the value of R
can be read precisely.
With the unknown in place, R
is adjusted until the galvanometer reads zero.
4
◀ Previous4 / 9Next ▶
The Wheatstone bridge
1

Points b and d are then at the same potential.
2

5
3

With no current through the galvanometer it has no effect on the rest of the circuit,
4

so the two branches act as parallel paths,
5

and each has the full source voltage across it.
6

Because b and d are at the same potential, the potential drop from a to b equals the drop from a to d.
◀ Previous5 / 9Next ▶
The Wheatstone bridge
1

Let I
2

be the current in the branch through b and I
3

the current in the branch through d.
4

Then I
5

R
6

= I
◀ Previous6 / 9Next ▶
The Wheatstone bridge
The Wheatstone bridge
.
In the same way, the drop from b to c equals the drop from d to c

so I
Taking the ratio of these two equations cancels both currents and gives R
/R
= R
Solving for the unknown resistance gives R
◀ Previous7 / 9Next ▶
The Wheatstone bridge
1

6
2

Every quantity on the right is known

so R
3

can be calculated.
4

7
5

Like the potentiometer, the bridge is limited by the difficulty of judging exactly when the galvanometer reads zero,
6

and by uncertainty in the known resistances,
◀ Previous8 / 9Next ▶
The Wheatstone bridge
The Wheatstone bridge
but it is far more precise than a simple ohmmeter.
◀ Previous9 / 9
1Check your understanding: limits of null measurements2Check your understanding: limits of null measurements
Check your understanding: limits of null measurements
Check your understanding: limits of null measurements
Other factors can limit the accuracy of a null measurement.
The wires and connections in the circuit have some resistance

which cannot be made exactly zero and can change over time.
Temperature also changes resistances.
Choosing a suitable material reduces this effect

but cannot eliminate it completely.
A digital device that is sensitive to smaller currents than a galvanometer does improve a null measurement,
because it lets the current be set closer to zero and the balance point be judged more precisely.
1 / 2Next ▶
Check your understanding: limits of null measurements
1

A Wheatstone bridge can be very accurate, often to four significant digits.
2

It is still limited in two ways.
3

First, the galvanometer current can never be made exactly zero.
4

Second, the known resistances always carry some uncertainty, and that uncertainty passes into the calculated unknown resistance.
◀ Previous2 / 2
Example 1: Unknown emf with a potentiometer · Example 2: Unknown resistance with a Wheatstone bridge
Example 1: Unknown emf with a potentiometer
A standard emf of 1.018 V balances at a wire length of 60.0 cm. An unknown cell balances at 45.0 cm. Find the emf of the unknown cell.
Use εx = εs(Lx/Ls). Then εx = 1.018 V × (45.0 cm / 60.0 cm) = 1.018 V × 0.750 = 0.764 V. The unknown cell has an emf of about 0.764 V.
Example 2: Unknown resistance with a Wheatstone bridge
In a balanced bridge, R1 = 100 Ω, R2 = 200 Ω and the variable resistor reads R3 = 300 Ω. Find the unknown resistance Rx.
Use Rx = R2R3/R1. Then Rx = (200 Ω)(300 Ω)/(100 Ω) = 600 Ω. The unknown resistance is 600 Ω.
Key terms
Term Meaning
Null measurement A measurement that adjusts a known quantity until the detecting device reads zero, so that no current is drawn from the circuit being measured.
Potentiometer A null device that measures an unknown emf by balancing it against the potential drop along a long, uniform wire.
Galvanometer A very sensitive meter that detects extremely small currents; in null measurements it is used only to show when the current is zero.
Emf (electromotive force), ε The energy supplied per unit charge by a source of electricity, measured in volts.
Terminal voltage, V The voltage across the terminals of a source when current flows; it is smaller than the emf by the amount Ir.
Internal resistance, r The resistance inside a real source, measured in ohms, which causes its terminal voltage to fall as the current increases.
Standard emf, εs An emf whose value is known very precisely, used as a reference when measuring an unknown emf with a potentiometer.
Balance point The position of the contact on a potentiometer, or the setting of a bridge, at which the galvanometer reads zero.
Ohmmeter A meter that finds resistance by applying a voltage to a resistor, measuring the current and calculating R = V/I.
Wheatstone bridge A null device with two branches that balances potential drops so that an unknown resistance can be calculated from three known resistances.
1Avoid these mistakes2Avoid these mistakes3Avoid these mistakes4Avoid these mistakes
Avoid these mistakes
1Avoid this
Believing that a null measurement reads a current. At balance the galvanometer reads zero, and the unknown source delivers no current to the detector.Avoid this
2Avoid this
Reading the emf directly from a voltmeter across a battery.Avoid this
The reading is the terminal voltage V = ε − Ir, which is smaller than the emf whenever current flows.Avoid this
3Avoid this
1 / 4Next ▶
Avoid these mistakes
Swapping the balance lengths in the potentiometer equation.Avoid this
The unknown emf uses the ratio εs(Lx/Ls), so the standard length must go in the denominator.Avoid this
4Avoid this
Assuming that a galvanometer reading of zero means the emf is zero. A zero reading only means that no current flows through the detector.Avoid this
5Avoid this
Placing the resistors in the wrong positions in a Wheatstone bridge and getting RAvoid this
◀ Previous2 / 4Next ▶
Avoid these mistakes
xAvoid this
= RAvoid this
RAvoid this
/RAvoid this
instead of RAvoid this
.Avoid this
◀ Previous3 / 4Next ▶
Avoid these mistakes
Always check which resistors sit in the same branch as the unknown.Avoid this
6Avoid this
Expecting a null method to give an exact result.Avoid this
Judging the zero reading and knowing the standard values still introduce uncertainty,Avoid this
although it is much smaller than with a direct voltmeter reading.Avoid this
◀ Previous4 / 4
Accepted payment methods