Curriculum
Course: OCR A Level Physics A H556
Login

Curriculum

OCR A Level Physics A H556

1. Development of Practical Skills in Physics

0/56 Dr Dabour Hub Science Diagram and Course Material

2. Foundations in Physics

0/29 Dr Dabour Hub Science Diagram and Course Material

3. Forces and Motion

0/108 Dr Dabour Hub Science Diagram and Course Material

4. Electrons, Waves and Photons

0/71 Dr Dabour Hub Science Diagram and Course Material
Text lesson

1.2.2 Analysing Quantitative Data

1.2.2 Analysing Quantitative Data — OCR A Level Physics A notes: Process numerical results using means, ranges, percentage differences and percentage uncertainties, and combine uncertainties correctly.

1From readings to a result2Uncertainty3Uncertainty
From readings to a result
From readings to a result
Analysis turns a table of readings into a single quantity with an honest statement of how well it is known.
1 / 3Next ▶
Uncertainty
1

Every measurement has an
2

uncertainty
3

, a range within which the true value is expected to lie.
4

A result is written as
5

x
6

= (value ± uncertainty) unit, with the uncertainty usually given to one significant figure and the value rounded to the same decimal place.
◀ Previous2 / 3Next ▶
Repeat readings with mean, range and error bars on a dot plot
Uncertainty
◀ Previous3 / 3
Mean, range and random uncertainty
Mean, range and random uncertainty
When a measurement is repeated, the mean is the best estimate of the true value: mean = sum of readings / number of readings. The spread is described by the range (largest minus smallest). A simple, accepted estimate of the absolute uncertainty in the mean is half the range:
uncertainty in mean ≈ (maximum − minimum) / 2.
For a single reading the uncertainty is limited by the instrument. A reasonable convention at A Level is ± half the smallest scale division for an analogue scale, or ± one smallest digit for a digital meter

but you must sometimes judge the larger of that and the reaction-time or judgement uncertainty.
1Absolute, fractional and percentage uncertainty2Fractional uncertainty3Fractional uncertainty
Absolute, fractional and percentage uncertainty
Absolute, fractional and percentage uncertainty
The absolute uncertainty Δx has the same unit as x.
1 / 3Next ▶
Fractional uncertainty
1

The
2

fractional uncertainty
3

is Δ
4

x
5

/
6

and the
◀ Previous2 / 3Next ▶
Fractional uncertainty
Fractional uncertainty
percentage uncertainty
is (Δ
) × 100%.
Percentage uncertainty is the best way to judge the quality of a measurement: a 1 mm error on a 2 mm gap is terrible

but on a 2 m length it is negligible.
◀ Previous3 / 3
1Combining uncertainties2Adding or subtracting3Adding or subtracting4Adding or subtracting · Multiplying or dividing5Raising to a power6Raising to a power
Combining uncertainties
Combining uncertainties
When a result is calculated from several measurements, uncertainties combine by simple rules:
1 / 6Next ▶
Adding or subtracting
Adding or subtracting
quantities:
add the absolute uncertainties
. If
z
=
◀ Previous2 / 6Next ▶
Adding or subtracting
Adding or subtracting
a
−
b
then Δ
= Δ
+ Δ
◀ Previous3 / 6Next ▶
Adding or subtracting · Multiplying or dividing
Adding or subtracting
. Subtraction does not reduce uncertainty.
Multiplying or dividing
add the percentage uncertainties
.
◀ Previous4 / 6Next ▶
Raising to a power
1

n
2

: multiply the percentage uncertainty by |
3

|. For
4

2
5

, % uncertainty in
◀ Previous5 / 6Next ▶
Raising to a power
Raising to a power
= 2 × % uncertainty in
A constant with no uncertainty (such as 2 or π) contributes no uncertainty by itself.
Because the larger percentages dominate, improve the measurement with the biggest percentage uncertainty first.
◀ Previous6 / 6
1Percentage difference and comparing values2Percentage difference and comparing values3Percentage difference and comparing values
Percentage difference and comparing values
Percentage difference and comparing values
To compare an experimental value with an accepted value use percentage difference = |experimental − accepted| / accepted × 100%.
1 / 3Next ▶
Percentage difference and comparing values
Percentage difference and comparing values
A conclusion is only meaningful when this is compared with the percentage uncertainty: if the difference is smaller than the uncertainty, the result agrees within experimental error

if larger, there is probably a systematic error.
This leads into
Evaluating Results and Drawing Conclusions
(1.2.4).
Useful analysis steps are: calculate means

discard (and report) clear anomaliescompute the derived quantitycalculate its percentage uncertaintyand state the final result with unit and appropriate significant figures.
Standard form lets very large or very small quantities be written compactly, and the prefixes for powers of ten must be known.
◀ Previous2 / 3Next ▶
Percentage difference and comparing values
Percentage difference and comparing values
Calculated results should be given to a sensible number of significant figures, and all values in one column should share the same count.
When a mean is taken from repeat readings, it is acceptable to keep one more significant figure than the readings have.
If a relationship obeys y = mx + c, the gradient and y-intercept can be analysed to draw conclusions.
The area under a graph can be estimated, including for curves that are not straight lines.
The gradient at any point on a curve is found by drawing a tangent and calculating its gradient

giving an instantaneous rate of change.
Logarithmic plots can be used to interpret relationships, and asymptotes may need to be recognised on a graph.
◀ Previous3 / 3
1A step-by-step method2A step-by-step method3A step-by-step method4A step-by-step method
A step-by-step method
1

When you meet a data-analysis question, work through the same routine each time.
2

1
3

First, list what was measured, with its unit and absolute uncertainty.
4

2
5

Second, convert everything to consistent units, preferably SI.
6

3
1 / 4Next ▶
A step-by-step method
1

Third, calculate any means and check the repeat readings for an outlier.
2

4
3

Fourth, work out the final quantity using the equation, keeping at least one extra significant figure until the last step.
4

5
5

Fifth, convert each absolute uncertainty to a percentage, combine them using the add-the-percentages rule for products and quotients, and convert the total back to an absolute uncertainty.
6

6
◀ Previous2 / 4Next ▶
A step-by-step method
A step-by-step method
Finally, round the uncertainty to one significant figure and quote the result to the same decimal place, for example 2.51 ± 0.10 g cm
−3
becomes 2.5 ± 0.1 g cm
.
7
Writing each stage out makes it easy for an examiner to award method marks even if a slip occurs in the arithmetic.
◀ Previous3 / 4Next ▶
A step-by-step method
A step-by-step method
It is also worth checking that the answer is sensible: a density of copper that comes out as 89 g cm−3 signals a unit or arithmetic error.
◀ Previous4 / 4
1Worked examples2Worked examples3Worked examples4Worked examples
Worked examples
Worked examples
Worked example 1. A student measures the diameter of a wire with a micrometer five times: 0.52, 0.53, 0.52, 0.54, 0.51 mm. Find the mean diameter and the percentage uncertainty.
1
Mean = (0.52 + 0.53 + 0.52 + 0.54 + 0.51)/5 = 2.62/5 = 0.524 mm.
2
Range = 0.54 − 0.51 = 0.03 mm

so uncertainty = 0.015 mm, about ±0.02 mm.
3
1 / 4Next ▶
Worked examples
Worked examples
Percentage uncertainty = 0.015/0.524 × 100% = 2.9%.
4
Result: d = (0.52 ± 0.02) mm.
Worked example 2. The density of a metal cylinder is ρ = m / (πr2h). Given m = 85.0 g ± 0.1 g, r = 1.20 cm ± 0.02 cm, h = 7.50 cm ± 0.05 cm, find the density and its percentage uncertainty.
Volume = π × 1.202 × 7.50 = 33.9 cm3. Density = 85.0 / 33.9 = 2.51 g cm−3.
% uncertainties: m: 0.1/85.0 = 0.12%

r: 0.02/1.20 = 1.67%, doubled to 3.3%h: 0.05/7.50 = 0.67%.
◀ Previous2 / 4Next ▶
Worked examples
1

Total = 0.12 + 3.3 + 0.67 = 4.1%

which is ±0.1 g cm−3.
2

ρ = (2.5 ± 0.1) g cm−3. The radius dominates

so measure it more precisely.
3

Worked example 3. The extension of a spring is found as final length 32.4 cm minus original length 20.1 cm, each ±0.1 cm. Find the extension and its percentage uncertainty.
4

Extension = 32.4 − 20.1 = 12.3 cm.
5

Absolute uncertainty = 0.1 + 0.1 = 0.2 cm.
6

Percentage = 0.2/12.3 × 100% = 1.6%.
◀ Previous3 / 4Next ▶
Worked examples
Worked examples
Extension = (12.3 ± 0.2) cm.
◀ Previous4 / 4
Key terms
Term Meaning
Absolute uncertainty The uncertainty expressed in the units of the measured quantity.
Percentage uncertainty Absolute uncertainty divided by the measured value, times 100%.
Range Largest reading minus smallest reading in a set of repeats.
Percentage difference Gap between experimental and accepted value as a percentage of the accepted value.
Derived quantity A quantity calculated from other measured quantities.
Random uncertainty Scatter in repeated readings that varies unpredictably.
1Avoid these mistakes2Avoid these mistakes
Avoid these mistakes
1Avoid this
Subtracting uncertainties when two quantities are subtracted. Absolute uncertainties always add.Avoid this
2Avoid this
Forgetting to multiply the percentage uncertainty by the power when a quantity is squared or cubed.Avoid this
3Avoid this
Quoting an uncertainty to several significant figures, for example ±0.01234 m.Avoid this
1 / 2Next ▶
Avoid these mistakes
4Avoid this
Confusing absolute uncertainty with percentage uncertainty when adding them in a product.Avoid this
5Avoid this
Using the percentage difference from the accepted value as the uncertainty of the experiment.Avoid this
◀ Previous2 / 2
Accepted payment methods