6.2.5 Correcting Units

6.2.5 Correcting Units — EDEXCEL IAL PHYSICS (IAS & A2) notes: Use SI and derived units and prefixes correctly, convert units, check equations for consistent units and find units from graphs.

1Meaning · Where to state them · No units2Learning
Meaning · Where to state them · No units
Meaning
a value without its unit means nothing

because 5 mm and 5 km are very different.
Where to state them
always give units on answers, graph axes and table headings.
No units
some quantities, such as strain, refractive index and number of particles, have none.
1 / 2Next ▶
Learning
Learning
know the unit of each physical quantity, or derive it from an equation.
◀ Previous2 / 2
1Base units · Derived units · Common units2Deriving a unit
Base units · Derived units · Common units
Base units
metre (m), kilogram (kg), second (s), ampere (A) and kelvin (K) are most used.
Derived units
newton N = kg m s−2 and joule J = kg m2 s−2.
watt W = J s−1 and pascal Pa = N m−2.
volt V = J C−1 and ohm Ω = V A−1.
Common units
length in m, area in m2 and volume in m3.
1 / 2Next ▶
Deriving a unit
Deriving a unit
for resistivity ρ = RA/L, the unit is Ω × m2 ÷ m = Ω m.
◀ Previous2 / 2
Units of Length in mm
Correcting wrong units
Quantity Wrong unit Correct unit
Magnetic flux density Weber Tesla (T)
Electromotive force N Volt (V)
Capacitance μC Microfarad (μF)
Stress m2 Pascal (Pa)
1Powers of ten · Small prefixes · Care2Standard form
Powers of ten · Small prefixes · Care
Powers of ten
tera T (1012), giga G (109), mega M (106), kilo k (103).
Small prefixes
centi c (10−2), milli m (10−3), micro μ (10−6), nano n (10−9), pico p (10−12).
Care
capital M is mega and lowercase m is milli.
1 / 2Next ▶
Number line of powers of ten showing SI prefixes from femto (10-15 to peta (1015, with the base unit at 100
Standard form
Number line of powers of ten showing SI prefixes from femto (10^-15) to peta (10^15), with the base unit at 10^0" loading= - Dr Khaled Dabour Academy⤢ Enlarge
Standard form
convert before calculating, for example 45 mA = 4.5 × 10−2 A and 2.2 MΩ = 2.2 × 106 Ω.
◀ Previous2 / 2
1Rule · Area · Volume2Density · Speed and time · Other units
Rule · Area · Volume
Rule
the conversion factor must be raised to the same power as the unit.
Area
1 cm = 10−2 m

so 1 cm2 = 10−4 m2 and 1 mm2 = 10−6 m2.
Volume
1 cm3 = 10−6 m3, and 1 L = 10−3 m3.
1 / 2Next ▶
Density · Speed and time · Other units
Density
1 g cm−3 = 103 kg m−3.
Speed and time
divide km h−1 by 3.6 to get m s−1, and use 1 h = 3600 s and 1 day = 86 400 s.
Other units
1 kWh = 3.6 × 106 J and 1 eV = 1.60 × 10−19 J.
◀ Previous2 / 2
1Homogeneous equation · Method · Limit2Rules
Homogeneous equation · Method · Limit
Homogeneous equation
every term must have the same units.
Method
replace each quantity by its base units and compare both sides.
E = ½mv2: kg (m s−1)2 = kg m2 s−2 = J.
T = 2π√(l/g): √(m/m s−2) = s.What the symbols mean: T = period (s) · l = length of the pendulum (m) · g = 9.81 m s−2
Limit
a homogeneous equation may still be wrong by a numerical factor

but an inhomogeneous one is certainly wrong.
1 / 2Next ▶
Rules
Rules
added or subtracted quantities need the same units, and the argument of a logarithm or exponential is a pure number.
◀ Previous2 / 2
1Gradient · Area · Prefixed axes2Logarithms
Gradient · Area · Prefixed axes
Gradient
it has units of the y-quantity divided by the x-quantity, such as V A−1 = Ω for a V–I graph.
Area
it has units of the product, such as N × m = J under a force–extension graph.
Prefixed axes
if the axis is I / mA, convert the gradient

so 2.5 V per mA is 2500 Ω.
1 / 2Next ▶
Logarithms
Logarithms
take logs of pure numbers, writing ln(x / m).
◀ Previous2 / 2
1Carry units · Final unit · Temperature2Angles
Carry units · Final unit · Temperature
Carry units
write each quantity with its unit and cancel them through the algebra.
Final unit
it checks the working, and a speed ending in m s−2 means an error.
Temperature
differences are the same in K and °C

but gas and radiation laws need kelvin.
1 / 2Next ▶
Angles
Angles
set the calculator to radians for ω = 2π/T and s = rθ.
◀ Previous2 / 2
1Dimensional consistency and calculation errors
  • Dimensional consistency and calculation errors checking base SI unit dimensions across physical equations eliminates mathematical substitution errors.
2Recording Raw Experimental Measurements
  • All raw measurements taken with apparatus such as a millimeter ruler or stopwatch must be documented to a consistent number of decimal places matching tool precision.
3Significant Figures in Calculated Results
  • Derived physical quantities must be expressed to the same number of significant figures as the least precise raw measurement utilized in the calculation.
4Identifying Anomalies Across the Range
  • Repeating measurements across an extended experimental range ensures anomalous readings can be identified, discarded from averages,
  • and repeated to ensure reliable conclusions.
5Precision in Timing Repeated Oscillations
  • Measuring the cumulative time for 10 or 20 complete oscillations and dividing by the cycle count reduces human reaction time error in period determinations.
6Significant figures in tables
  • Significant figures in tables all recorded readings in a data column must display an identical and consistent number of significant figures.
7Timing multiple oscillations
  • Timing multiple oscillations measuring the total time for ten complete oscillations significantly reduces the percentage uncertainty from human reaction time.
8Identifying anomalous results
  • Identifying anomalous results repeating measurements across the entire experimental range allows anomalous values to be spotted and discarded before averaging.
9Resolution
  • Smallest change an instrument can detect.
10Significant figures
  • Digits carrying meaningful information in a number.
11Fiducial marker
  • A fixed reference mark used to judge when an oscillating object passes its centre position.
12Repeat readings
  • Taking measurements again to reduce random error.
13Anomalous reading
  • A measurement that does not fit the pattern of the other data.
14Decimal place
  • A digit to the right of the decimal point.
15Potential difference
  • Work done by a unit charge passing through a component.
16Elastic limit
  • Greatest load a spring can recover from.
17Oscillation
  • Repeated back-and-forth motion.
18Current
  • Flow of electrons in a circuit.
Key terms
Term Meaning
SI unit Unit from the International System: m, kg, s, A, K, mol, cd.
Derived unit Unit made from base units, such as N = kg m s−2.
Prefix Multiplier such as kilo (103) or micro (10−6).
Homogeneous equation Equation with the same units in every term.
Standard form A × 10n with 1 ≤ A < 10.
1Avoid these mistakes2Avoid these mistakes
Avoid these mistakes
1Avoid this
Converting cm2 to m2 by dividing by 100 instead of 10 000.Avoid this
2Avoid this
Mixing up M (mega) and m (milli).Avoid this
3Avoid this
Using grams in equations that need kilograms.Avoid this
1 / 2Next ▶
Avoid these mistakes
4Avoid this
Assuming a homogeneous equation must be correctconstant factors can still be wrong.
5Avoid this
Forgetting to convert a graph gradient when the axes use prefixed values.Avoid this
◀ Previous2 / 2