Curriculum
Course: Edexcel IAL Physics (IAS & A2)
Login

Curriculum

Edexcel IAL Physics (IAS & A2)

1. Mechanics and Materials

0/71 Dr Dabour Hub Science Diagram and Course Material

2. Waves and Electricity

0/108 Dr Dabour Hub Science Diagram and Course Material

3. Practical Skills in Physics I

0/52 Dr Dabour Hub Science Diagram and Course Material

4. Further Mechanics, Fields and Particles

0/90 Dr Dabour Hub Science Diagram and Course Material

5. Thermodynamics, Radiation, Oscillations and Cosmology

0/96 Dr Dabour Hub Science Diagram and Course Material
Text lesson

3.1.8 Data Collection

3.1.8 Data Collection — EDEXCEL IAL PHYSICS (IAS & A2) notes: Record data in a well-designed table and process it using standard form, significant figures, means and straight-line graphs.

1Planning the collection2Planning the collection
Planning the collection
Plan
state what will be measured, how many times, in what order and how it will be recorded.
Table first
create a results table before starting so every measurement has a place.
Raw data
record readings directly

do not mentally round or alter them.
Processing
raw results often need calculations before they are meaningful, often to give a straight line y = mx + c.
1 / 2Next ▶
Example results table with headings, units and repeated readings for each variable
Planning the collection
◀ Previous2 / 2
1Headings · Order · Columns2Units · Decimal places
Headings · Order · Columns
Headings
quantity and unit in each heading, written like L / m or I / A.
Order
independent variable in the first column, in increasing order.
Columns
one for each repeat

then the meanthen any calculated quantities such as R = V/I or T2.
1 / 2Next ▶
Units · Decimal places
Units
none in the body of the table.
Decimal places
consistent in each column and matching the instrument resolution, e.g. 0.30 A not 0.3 A.
◀ Previous2 / 2
Standard form · Benefit · Prefixes
Standard form
large or small numbers are written as a × 10n, for example 3.00 × 108 m s-1.
Benefit
it avoids repeating many zeros.
Prefixes
know the prefixes for powers of ten.

(nano, micro, milli, kilo, mega, giga)
Significant figures · Columns · Mean values
Significant figures
report calculations to an appropriate number of significant figures.
Columns
all the data in a column should have the same number of significant figures.
Mean values
calculate the mean of repeat readings

it is acceptable to give it one more significant figure.
1Straight-line form · Area · Logarithmic plots2Tangents · Asymptotes · Background count
Straight-line form · Area · Logarithmic plots
Straight-line form
if a relationship obeys y = mx + c, the gradient and y-intercept can be analysed to draw conclusions.
Area
find the area under a graph, including non-linear graphs.
Logarithmic plots
use and interpret them.
1 / 2Next ▶
Tangents · Asymptotes · Background count
Tangents
draw them and calculate their gradient, e.g. instantaneous velocity from a displacement–time graph.
Asymptotes
understand where they may be required.
Background count
subtract the mean background from each reading before testing a relationship.
◀ Previous2 / 2
Order and efficiency
Sensible order
take readings in a sensible order

randomise if a hidden trend such as warming is possible.
Time intervals
for heating or cooling, take readings at regular time intervals.
Changeable variable first
measure the most changeable variable first if the equipment may drift.
Unusual events
write down anything unusual, and repeat a suspicious reading at once.
1Datalogger · Use · Sampling rate2Analysis
Datalogger · Use · Sampling rate
Datalogger
records values automatically at fixed intervals.
Use
for rapid changes, long experiments and to avoid reaction-time error.
Sampling rate
it must be fast enough to capture the change

an event lasting 0.1 s needs at least 100 samples per second.
1 / 2Next ▶
Analysis
Analysis
data can be exported to a spreadsheet for graphs.
◀ Previous2 / 2
More from the specification
Control of Variables in Scientific Investigations
  • In experimental design, control variables such as room temperature and wire length must be held constant to ensure valid relationships between the independent and dependent variables are determined.
Apparatus Selection and Measurement Range
  • Choosing laboratory apparatus with an appropriate range and resolution—such as a micrometer screw gauge for thin wires rather than a metre ruler—minimizes measurement uncertainty.
Systematic and Random Errors
  • Systematic errors bias all measured values in one direction,
    • (such as zero error on calipers or a miscalibrated thermometer)
  • whereas random errors create scatter around the true mean value.
Quantifying Experimental Uncertainty
  • Absolute uncertainty depends on instrument resolution,
  • and propagating percentage uncertainties through calculated quantities allows scientists to evaluate the reliability of experimental conclusions.
Control of Variables in Scientific Investigations
  • In experimental design, control variables such as room temperature and wire length must be held constant to ensure valid relationships between the independent and dependent variables are determined.
Apparatus Selection and Measurement Range
  • Choosing laboratory apparatus with an appropriate range and resolution—such as a micrometer screw gauge for thin wires rather than a metre ruler—minimizes measurement uncertainty.
Systematic and Random Errors
  • Systematic errors bias all measured values in one direction,
    • (such as zero error on calipers or a miscalibrated thermometer)
  • whereas random errors create scatter around the true mean value.
Quantifying Experimental Uncertainty
  • Absolute uncertainty depends on instrument resolution,
  • and propagating percentage uncertainties through calculated quantities allows scientists to evaluate the reliability of experimental conclusions.
Factor
  • A variable that affects something.
Balance
  • An instrument for comparing weights, used to find mass.
Control variable
  • A quantity kept the same to make the test fair
Systematic error
  • An error that shifts all readings the same way, such as a balance not zeroed.
Young modulus
  • Ratio of stress to strain for a material, E = σ/ε.
Calibration curve
  • A graph converting an instrument’s reading to the true value.
Potential difference
  • Work done by a unit charge passing through a component.
Apparatus
  • The equipment needed to carry out an experiment.
Length
  • Resistance is directly proportional to the length of a wire.
Temperature
  • Measure of the average kinetic energy of the particles.
Thermometer
  • A device that reaches equilibrium with an object to measure its temperature
Uncertainty
  • An estimate of the range in which the true value is expected to lie.
Micrometer
  • An instrument measuring very small lengths to 0.01 mm.
Voltmeter
  • Instrument that measures p.d., connected in parallel.
Calibration
  • Comparing readings with known fields to find the constant k
  • Safety
    • Keep electrical equipment away from water; wipe up spills; do not look directly at a bright strobe or lamp
Key terms
Term Meaning
Raw data The original readings recorded directly from instruments.
Standard form A number written as a × 10n.
Significant figures The digits of a number that carry meaningful information.
Datalogger A device that stores readings from sensors automatically.
Sampling rate The number of readings recorded per second.
1Avoid these mistakes2Avoid these mistakes
Avoid these mistakes
1Avoid this
Leaving units out of the column headings or writing them in each cell.Avoid this
2Avoid this
Recording different numbers of decimal places for the same instrument.Avoid this
3Avoid this
Not leaving space for repeats or calculated values.Avoid this
1 / 2Next ▶
Avoid these mistakes
4Avoid this
Altering or erasing raw readings instead of marking anomalies.Avoid this
◀ Previous2 / 2
Accepted payment methods