Curriculum
Course: Edexcel IAL Physics (IAS & A2)
Login

Curriculum

Edexcel IAL Physics (IAS & A2)

1. Mechanics and Materials

0/71 Dr Dabour Hub Science Diagram and Course Material

2. Waves and Electricity

0/108 Dr Dabour Hub Science Diagram and Course Material

3. Practical Skills in Physics I

0/52 Dr Dabour Hub Science Diagram and Course Material

4. Further Mechanics, Fields and Particles

0/90 Dr Dabour Hub Science Diagram and Course Material

5. Thermodynamics, Radiation, Oscillations and Cosmology

0/96 Dr Dabour Hub Science Diagram and Course Material
Text lesson

3.3.6 Reducing Errors

3.3.6 Reducing Errors — IAL Physics Notes — EDEXCEL IAL PHYSICS (IAS & A2) notes: Distinguish random and systematic errors and describe practical methods that reduce each.

1Types of error2Types of error
Types of error
Types of error
Random errors readings scatter unpredictably above and below the true value.
They arise from reaction time, fluctuating conditions and judging a pointer between marks.
They cannot be completely removed

but averaging many repeats reduces their effect.
Systematic errors all readings shift in the same direction by the same amount or proportion.
Examples are a zero error on a micrometer, a stopwatch that runs fast and a worn end on a metre rule.
Repeating readings does not reduce them.
1 / 2Next ▶
Types of error
Types of error
Human mistakes reading a scale wrongly or transposing digits is not a random error and is removed by care and checking.
◀ Previous2 / 2
1Accuracy · Precision · Resolution2Combination
Accuracy · Precision · Resolution
Accuracy
a result is accurate if it is close to the true value

which is limited by systematic error.
Precision
a result is precise if repeats agree closely

which is limited by random error.
Resolution
the smallest change an instrument can detect, such as 0.1 mm for a vernier or 0.01 V for a digital voltmeter.
1 / 2Next ▶
Combination
Combination
readings can be precise but inaccurate, such as a tight cluster offset by a zero error.
◀ Previous2 / 2
1Common limitations of a procedure2Common limitations of a procedure3Common limitations of a procedure
Common limitations of a procedure
1

1
2

Parallax error when reading scales.
3

2
4

No fiducial marker when timing a pendulum.
5

3
6

No repeat readings to reduce random error.
1 / 3Next ▶
Common limitations of a procedure
1

4
2

No check for zero errors to reduce systematic error.
3

5
4

Equipment not working properly because it was not tested beforehand.
5

6
6

Poor precision and resolution, such as a ruler used instead of a micrometer.
◀ Previous2 / 3Next ▶
Common limitations of a procedure
Common limitations of a procedure
7
Variables that are difficult to control, such as room temperature.
8
Unwanted heating effects in circuits.
◀ Previous3 / 3
Reducing random error
Repeats
repeat readings and take a mean, or use a graph so that many readings contribute to the gradient.
Many oscillations
time many oscillations and divide.
Finer resolution
use a micrometer instead of a ruler for a wire diameter.
Larger quantity
use a longer length so the fixed instrument uncertainty is a smaller fraction.
Data loggers and light gates
they remove reaction time.
1Reducing systematic error2Reducing systematic error
Reducing systematic error
Reducing systematic error
Zero error check digital and analogue instruments before measuring and correct every reading.
An ammeter must read 0 A with no current, and a micrometer reading 0.02 mm when closed means subtract 0.02 mm.
Calibration check the instrument against a known standard.
Parallax read a scale only with the line of sight perpendicular to it, at eye level.
It is common when reading the volume of a liquid, aligning two objects or reading a thermometer.
Fiducial marker a clear reference point at the centre of an oscillation improves timing.
1 / 2Next ▶
Reducing systematic error
Reducing systematic error
The pendulum moves fastest at the lowest point

where it is easiest to judge the moment of passing.
Graph a constant systematic error shows as a non-zero intercept and does not change the gradient.
Second method measure the same quantity by an independent method and compare.
◀ Previous2 / 2
Heating effect · Control variables · Wire radius
Heating effect
the resistance of a wire rises as it heats

which causes an error.
Switch off the power supply between readings to avoid it.
Control variables
state the variables kept constant and how.
Use the same wire at constant temperature while varying length.
Use the same mass of water throughout.
Wire radius
measure with a micrometer, not a ruler, and take 3 to 5 repeats at different points along the wire to check that it is uniform.
Diagnosing errors from data
1

Large differences between repeats random error is large.
2

Tight grouping but disagreement with the accepted value a systematic error is likely, such as a zero error, a miscalibration or ignored heat loss.
3

Scatter about the line of best fit greater scatter means more random error.
4

Intercept and gradient a fixed systematic error changes the intercept, and a proportional one changes the gradient.

(a stopwatch 2% fast)
5

A proportional error is found only by comparing with a second method.
More from the specification
Instrumental span across test range
  • Instrumental span across test range selecting digital meters with high sensitivity reduces parallax while maintaining precision across the test range.
Techniques for Reducing Experimental Errors
  • Systematic errors can be minimized by zeroing instruments and calibrating equipment before an experiment,
  • while random errors are reduced by using high-resolution measuring devices, taking repeat trials,
  • and using fiducial markers.
Calculating Absolute and Percentage Uncertainties
  • The percentage uncertainty in a measurement is given by × 100%;
    • (Absolute Uncertainty / Measured Value)
  • when quantities are multiplied or divided in an equation, their percentage uncertainties are added together,
  • while squaring a variable doubles its percentage uncertainty.
Linearising Graphs and Dimensional Analysis
  • When two physical variables obey an inversely proportional (y ∝ 1/x) or inverse-square relationship (y ∝ 1/x2), plotting y against 1/x or 1/x2 linearises the data into a straight line through the origin, with clear axis labels including appropriate physical units.
Inverse square law relationship
  • Inverse square law relationship radiation intensity decreases inversely with distance squared from sources, verified by plotting count rate against inverse distance squared.
Percentage uncertainty on measurements
  • Percentage uncertainty on measurements percentage uncertainty equals absolute instrument error divided by measured experimental value multiplied by one hundred percent.
Graph axis formatting and units
  • Graph axis formatting and units experimental graphs require clearly labelled axes indicating physical quantities alongside appropriate metric SI units.
Percentage uncertainty
  • The absolute uncertainty divided by the value, times 100%.
Inversely proportional
  • One quantity falls as the other rises in the same ratio.
Significant figures
  • Digits carrying meaningful information in a number.
Derived unit
  • A unit formed by multiplying or dividing SI base units.
Labelled practical setup marking random and systematic error sources with fixes" loading= - Dr Khaled Dabour Academy
Labelled practical setup marking random and systematic error sources with fixes
Key terms
Term Meaning
Random error An unpredictable variation in readings about the true value.
Systematic error An error that shifts all readings in one direction.
Zero error A systematic error where an instrument reads non-zero for zero input.
Parallax Apparent shift in a reading caused by viewing at an angle.
Precision How closely repeat readings agree.
Resolution Smallest change an instrument can show.
1Avoid these mistakes2Avoid these mistakes
Avoid these mistakes
1Avoid this
Saying repeats remove a systematic errorthey only reduce random error.
2Avoid this
Confusing accuracy with precisionaccuracy is closeness to the true value, precision is agreement of repeats.
3Avoid this
Applying a zero-error correction with the wrong signsubtract a positive zero reading.
1 / 2Next ▶
Avoid these mistakes
4Avoid this
Writing “be more careful” as an improvementgive a specific method.
5Avoid this
Treating a non-zero intercept as random errorit is likely a systematic error.
◀ Previous2 / 2
Accepted payment methods