Curriculum
Course: Edexcel IAL Physics (IAS & A2)
Login

Curriculum

Edexcel IAL Physics (IAS & A2)

1. Mechanics and Materials

0/71 Dr Dabour Hub Science Diagram and Course Material

2. Waves and Electricity

0/108 Dr Dabour Hub Science Diagram and Course Material

3. Practical Skills in Physics I

0/52 Dr Dabour Hub Science Diagram and Course Material

4. Further Mechanics, Fields and Particles

0/90 Dr Dabour Hub Science Diagram and Course Material

5. Thermodynamics, Radiation, Oscillations and Cosmology

0/96 Dr Dabour Hub Science Diagram and Course Material
Text lesson

3.1.4 Measuring Variables

3.1.4 Measuring Variables — EDEXCEL IAL PHYSICS (IAS & A2) notes: Identify the variables in an investigation and choose the most appropriate instrument and technique to measure each.

1Types of variable2Types of variable
Types of variable
Types of variable
Independent variable
the variable deliberately changed by the experimenter.
Dependent variable
the variable measured as the response.
Control variables
other quantities that could affect the result and must be kept constant.
1 / 2Next ▶
Types of variable
Types of variable
Example for a pendulum, length is independent, period is dependent, and bob mass, amplitude and location are controlled.
◀ Previous2 / 2
1Aim · Key factor2Too coarse
Aim · Key factor
Aim
use the most appropriate instrument and technique to obtain the most accurate value of each measurement.
Key factor
the resolution of the instrument.
1 / 2Next ▶
Side view of a mm scale with a pointer, showing a correct reading from an eye directly above and a parallax error from an eye at an angle
Too coarse
Side view of a mm scale with a pointer, showing a correct reading from an eye directly above and a parallax error from an eye at an angle" loading= - Dr Khaled Dabour Academy⤢ Enlarge
Too coarse
if the resolution is too big, small measurements cannot be made.
◀ Previous2 / 2
Circuit diagram with a cell, an ammeter in series with the current arrow, a component, and a voltmeter in parallel across the component
Apparatus and purpose
Instrument Purpose Example
Metre ruler Length between 1 cm and 1 m Length of a wire
Vernier calipers Short lengths, 0.1 mm to 1 cm Extension of a wire
Micrometer screw gauge Very short lengths, 0.01 mm to 0.1 mm Diameter of a wire
Top-pan balance Mass of an object Mass of a block
Protractor Angles Angle of refraction of a light beam
Stopwatch Time Time for an oscillation
Thermometer Temperature Temperature rise in a specific heat capacity experiment
Voltmeter Potential difference P.d. across a bulb
Ammeter Current Current through a bulb
Oscilloscope Display waves and measure frequency Frequency of a signal
Laser Monochromatic, coherent light Interference of light
Few cm to 1 m · 0.1 mm to a few cm · 0.01 mm to 0.1 mm
Few cm to 1 m
use a ruler.
0.1 mm to a few cm
use a Vernier caliper.
0.01 mm to 0.1 mm
use a micrometer.
Independent variable · Dependent variable · Number of values
Independent variable
state the range, the step size and the instrument, for example change the length from 0.20 m to 1.00 m in 0.10 m steps with a metre rule.
Dependent variable
state the instrument and method, for example time 20 oscillations with a stopwatch and divide by 20.
Number of values
use enough values to see the pattern, at least five or six.
1Linearise · Axes · State the meaning2Examples3Examples
Linearise · Axes · State the meaning
Linearise
choose a relationship that gives a straight line, for example T2 against l for a pendulum.
Axes
the independent variable goes on the x-axis and the dependent variable on the y-axis.
State the meaning
say what the gradient and intercept will represent.
1 / 3Next ▶
Examples
Examples
R against L has gradient ρ/A

I against 1/d2 for the inverse square lawln N against t has gradient −λ.
Only the independent variable should be able to change the dependent variable for an experiment to be a fair test.
Temperature is a common control variable in circuits unless a thermistor is used

because current warms wires and components over time.
Components are often disconnected between readings so that they can cool down and keep temperature constant.
Checking that a meter reads zero before measurements are made helps avoid zero error.
Typical resolutions are 1 mm for a metre ruler, 0.1 mm for Vernier calipers and 0.01 mm for a micrometer screw gauge.
◀ Previous2 / 3Next ▶
Examples
Examples
A single reading from a digital instrument has an uncertainty of half its resolution.
Calibration curves are needed when an instrument’s output is not proportional to the quantity it measures, as with a thermistor.
Measuring devices lose accuracy over time through normal wear and tear, and calibration improves accuracy.
◀ Previous3 / 3
More from the specification
Systematic vs random errors
  • Systematic errors cause experimental readings to deviate from the true value by a consistent amount or fraction,
    • (e.g. zero error or miscalibration)
  • whereas random errors cause unpredictable fluctuations around the mean.
Repeat measurements and reliability
  • Taking repeat readings of experimental variables and calculating the arithmetic mean reduces the effect of random errors and improves the precision of measurements.
Absolute and percentage uncertainty
  • The uncertainty of a single reading with an analogue scale is typically half the smallest division,
  • while for repeated measurements it is half the range; combining uncertainties when raising quantities to a power requires multiplying percentage uncertainty by the exponent.
Graphical representation of experimental data
  • Plotting experimental measurements on a graph with error bars allows visual identification of anomalous data points, zero offsets,
  • and gradients representing physical constants.
Repeat readings
  • Taking measurements again to reduce random error.
Systematic error
  • An error that shifts all readings the same way, such as a balance not zeroed.
Young modulus
  • Ratio of stress to strain for a material, E = σ/ε.
Calibration curve
  • A graph converting an instrument’s reading to the true value.
Significant figures
  • Digits carrying meaningful information in a number.
Apparatus
  • The equipment needed to carry out an experiment.
Uncertainty
  • An estimate of the range in which the true value is expected to lie.
Error
  • The difference between a measurement and the true value.
Calibration
  • Comparing readings with known fields to find the constant k
  • Safety
    • Keep electrical equipment away from water; wipe up spills; do not look directly at a bright strobe or lamp
Key terms
Term Meaning
Independent variable The variable deliberately changed by the experimenter.
Dependent variable The variable measured as the outcome.
Control variable A quantity kept constant so it does not affect the result.
Resolution The smallest increment an instrument can measure.
Linearisation Rearranging an equation into the form y = mx + c.
1Avoid these mistakes2Avoid these mistakes
Avoid these mistakes
1Avoid this
Mixing up independent and dependent variablesthe one you change is independent.
2Avoid this
Failing to name the instrument or its resolution for a variable.Avoid this
3Avoid this
Choosing only three values of the independent variablethis cannot show whether a trend is linear.
1 / 2Next ▶
Avoid these mistakes
4Avoid this
Forgetting to state which graph will be plotted and what its gradient means.Avoid this
◀ Previous2 / 2
Accepted payment methods